inVENTer Connect controller platform | Installation instructions
INSTALLING THE DEVICES
Connecting the mains cable and fan cable
DANGER
Exposed electrical components.
Electric shock and injury due to live components (230V, 50Hz)!
•
Before working on electrical installations, disconnect all affected equipment from the power supply.
• Observe the requirements for protection class II when laying the power supply cable.
Do not lay live cables.
• Lay the mains connection cables and data cables separately.
Installation and connection must only be performed by qualified and trained personnel.
Stripping tool, small slotted screwdriver
Requirements:
• The holding plate is mounted in the housing.
►
Shorten the mains connection cable to the required
length and strip approx. 7 mm of insulation with the
stripping tool.
►
Fix this cable (blue/brown) in the screw terminal on
the electronics of the holding plate:
• Connect the phase conductor with cable L
(brown).
• Connect the neutral conductor with cable N
(blue).
The mains connection cable is installed.
Requirements:
• A thermal accumulator insert of the inVENTer venti-
lation system is mounted in the wall sleeve accord-
ing to the corresponding installation instructions.
►
Connect the cables (blue, red, black) to the plug-in
connector of the ventilation device.
NOTE:
Fan cable connection.
• When connecting, always make sure that
the cable with the colour coding correspond-
ing to the assignment is inserted into the
corresponding socket!
The fan cable is installed.
230 V AC
L N
L N
blau
rot
schwarz
blau
rot
schwarz
blue
red
black
blue
red
black
The mains connection cable, fan cable (fan BUS connecting cable, 3-wire) and the motor cable for
the locking arm are connected to the holding plate of the inner cover.