36
INSTALLATION AND ASSEMBLY
36
iV-Smart+ ventilation device | Installation instructions
►
Insert the rawl plugs.
►
Screw the base plate into the rawl plugs with the
screws.
The position arrow on the base plate points
upwards.
TIP
: Optionally, the inner cover can be
screwed to the tabs of the base plate,
e.g. when using the wall installation block or
the Simplex wall installation system. In this
case, use rawl plugs suitable for insulation.
Ensure you install the dust filter properly to avoid a
malfunction of the ventilation device.
► Insert the dust filter into the base plate.
•
Push the filter ring firmly between the
fixing tabs and the inner edge of the
base plate.
•
The tab on the filter ring faces the inside
and is located in the cut-out provided in
the base plate.
►
Place the panel on the four spacers.
The position arrows on the back of the
inner cover panel point upwards.
Check:
The inVENTer logo is located at the
bottom right.
►
Press the locking lugs inwards on the spacers.
►
Slide the inner cover panel onto the spacers.
All spacers noticeably snap in.
The inner cover is fitted.
i
4 x
4 x CLICK
!
!
!
!