background image

22

INSTALLATION AND ASSEMBLY

22

iV-Smart+ ventilation unit | Installation instructions

1.1  Installing the wall sleeve

Measuring tape, angle grinder, spirit level, non-pressing 2K polyurethane foam, cutter, 

mounting wedge set and styrofoam discs

 

Cut the wall sleeve to the  

determined dimension 

X + 

a protrusion of Y

  

on the exterior wall.

Be careful not 

to cut away the cut-out for 

the fan connecting cable.

in [mm]

 =

in [mm]

 =

Inner cover

External termination

Flair

Connect AP

Connect UP

Undercover

Standard

A + B + C + D

A + B + C + D - 38

10

Corner

A + B

A + B - 38

10

A + B

A + B - 38

UBP + 10 

(for installation with UBP 

substructure panel)

Nordic

double-shell  

masonry  

(clinker brick)

A + B

A + B - 38

C + D - 200 

(min. 30 mm)

single-shell  

masonry (ETICS)

A + B

A + B - 38

C + D - 95 

(min. 30 mm)

Requirements:

• 

The wall opening Ø 180 mm is finished.

•  The cables to the wall opening of the ventilation unit 

have been laid.

 

Determine the exact wall thickness X: 

D = Exterior rendering, incl. other superstructures 

       if applicable. 

C = Insulation, if necessary incl. air gap 

B = Masonry, incl. relining if necessary 

A = Interior plaster 

Y = Protrusion of the wall sleeve in the outer 

       area (depending on the installation situation  

       exterior rendering or masonry)

!

X = ?

Y

D

A

B

C

+ Y

Summary of Contents for iV-Smart+

Page 1: ...www inventer de Installation instructions iV Smart ...

Page 2: ...ay still occur therefore no guarantee of compliance can be provided This documentation describes the functionality of the standard scope For reasons of clarity the documentation does not purport to cover all details on all types of the product and cannot cover every conceivable scenario for installation and assembly The illustrations in this document may differ slightly from the design of the prod...

Page 3: ...f supply 18 4 2 Create wall opening 19 4 3 Laying the cables to the wall opening of the ventilation unit 20 4 4 Installing the wall sleeve 22 4 5 Installing the external termination of the standard ventilation unit variant 25 4 6 Inserting the thermal accumulator insert 30 4 7 Electrical connection of the reversible fan 31 4 8 Check function and complete fan installation 33 4 9 Installing the inne...

Page 4: ...ates the severity of the potential hazard unless the preventive measures are taken DANGER means Imminent danger of serious injury or death WARNING means Possible danger of serious injury or death CAUTION means Direct danger of minor significant injury NOTICE means Direct or possible risk of property damage due to an adverse event state If you see these signs ensure you observe the described measur...

Page 5: ...conjunction with components that are recommended authorised and described by inVENTer GmbH in this documentation Changes or modifications to the unit system are not permitted Your ventilation system is exclusively designed for use in ambient temperatures between 20 and 50 C Trouble free and safe operation of the unit system depends on proper transportation proper storage and installation as well a...

Page 6: ...apes We recommend a biocidal pre treatment water repellent pre treatment of the façade surface around the external termina tions Consult your planner about this NOTICE When installing components in exterior walls with insulation use insulation wall plugs to ensure that the components are securely fastened Insulation wallplugs are not included in the scope of supply they are available as an option ...

Page 7: ...be set up operated and cleaned in conjunction with this docu mentation and the documentation for the controllers Installation electrical connection and commissioning of the equipment system may only be performed by qualified personnel Qualified personnel within the meaning of the safety notices in this documentation are persons who are authorised to install put it into operation and identify equip...

Page 8: ...d the Xenion reversible fan The guiding vanes on both sides of the fan serve to straighten the air flow and ensure more efficient flow through the thermal accumulator The unique geometry of the Xenion reversible fan effectively reduces sound transmission The standard length of the wall sleeve is 495 mm For thicker walls a wall sleeve with a length of 745 mm can be ordered Both versions can be shor...

Page 9: ...riving rain proof weather protection hood Corner variant iV Smart Corner ventilation units hereinafter referred to as the Corner variant for integration of the external termination in the window reveal white grey anthracite custom colour Nordic variant iV Smart Nordic variants in the further text Nordic variant for the integration of the external termination in clinker brick walls white grey anthr...

Page 10: ...protection hood cover 3 Drip rail 4 R D160 wall sleeve 5 Recess for controller connecting cable 6 Thermal accumulator with insulation 7 Thermal accumulator handle 8 Standard guiding vane wide 9 Xenion reversible fan 10 Slim guiding vane narrow 11 Guiding vane knob 12 BUS plug connection 180 External termination Smart Flex1 weather protection hood 13 Inner cover base plate 14 ISO Coarse 60 dust fil...

Page 11: ...weather related pressure fluctuations Thus the sensitivity of the air flow to pressure fluctuations corresponds to class S3 according to EN 13141 8 max 30 air flow deviation at 20 Pa In order to ensure the full functioning of the ventilation unit throughout the entire year a tempera ture sensor is integrated into the Xenion reversible fan This measures the temperature of the air flow at the fan If...

Page 12: ...n Pause function OFF standard only Heat recovery Through ventilation Dehumidification integrated moisture temperature sensor Pause function OFF Heat recovery Through ventilation Dehumidification and other demand ventilation Pause function global and zonal Boost function global and zonal OFF Fan speed infinitely adjustable 4 levels predefined 4 power levels freely selectable 4 power levels freely s...

Page 13: ...llation location Minimum distances of the wall opening for the ventilation unit Minimum distances to components building elements on the internal and external wall NOTICE Malfunction due to incorrect positioning of the ventilation unit Note insulation thickness and possibly shutters Do not install near radiators Observe minimum distance of 1 2 m to adjacent air openings Termination component Dista...

Page 14: ... iV Smart wall opening interior view with Smart weather protection hood top and Flex weather protection hood bottom 1 Wall opening Fig 2 left top and bottom Simplex wall installation system Fig 2 right 2 Contour of weather protection hood3 3 Reveal 4 Door window frame 5 Bottom edge of lintel4 1 Minimum distance to adjacent components on the interior wall 3 Recommendation Attach the hood at lintel ...

Page 15: ...f the iV Smart standard variant ventilation unit Figure 3 Sectional drawing of the iV Smart ventilation unit with Smart optional Flex weather protection hood B Interior plaster interior structure C Masonry D Insulation E Render 1 Inner cover base plate 2 Inner cover panel 3 R D160 wall sleeve 4 Smart weather protection hood 5 End stop tape 6 Thermal accumulator 7 inVENTron Xenion reversible fan em...

Page 16: ...ll 3 Drip rail 4 Panel fixing screws 4x 5 Weather protection hood panel Flex weather protection hood Flex weather protection hood panel Flex weather protection hood base plate Figure 5 Dimensional drawing of Flex weather protection hood 1 Weather protection hood base plate 2 Fixing hole exterior wall 4x 3 Simplex fixing hole 4x 4 Sealing strip guide 5 Weather protection hood panel 6 Protective gri...

Page 17: ...4 Inner cover base plate 5 Spacer 4 x 6 Interior wall fixing borehole 1 1 Dimensions Designation Depth length mm Width mm Height mm Wall opening for wall sleeve Wall thickness1 Ø180 R D160 wall sleeve 495 745 Ø160 Smart weather protection hood 43 222 285 Flex weather protection hood 23 88 279 313 Flair V 233x233 inner cover 612 233 233 1 Standard variant with render insulation masonry and plaster ...

Page 18: ...ions for the respective system component The Smart and Flex weather protection hoods are available in different colours the Flex weather protection hood additionally in different materials stainless steel aluminium with increased salt resistance and must be ordered according to the desired colour and texture Figure 7 iV Smart ventilation unit standard components 1 Weather protection hood external ...

Page 19: ...te the wall opening through core drilling Drill with core drill attachment or milling drill Ø 180 mm additionally if flush mounted inner cover is installed chisel Requirements The masonry must be dry and in a load bearing condition No load bearing elements in the position of the drill hole NOTICE Accumulation of condensate in the wall sleeve leads to damage to the brick work and exterior wall Crea...

Page 20: ...one inVENTer Connect Connect inner cover Connect inner cover operating voltage Installation cable 230 V AC e g NYM J 3x1 5 mm House distribution ventilation sub distribution Unit communication only if the system compo nents communicate by cable otherwise radio RS485 data cable e g Type J Y ST Y 2x2x0 8 mm Easy Connect e16 operating unit Once the wall opening has been created the cables necessary f...

Page 21: ...er cover Operating unit Easy Connect e16 System communication by cable RS485 data cable Cross section 0 25 0 5 mm Length max 500 m Cable NYM J wire cross section 1 5 mm Ventilation unit n Control unit Connect inner cover Ventilation unit 1 Control unit Connect inner cover House distributor Operating unit Easy Connect e16 230 V AC One after the other Star shaped Cable type LiYY 3 wire wire cross se...

Page 22: ...dard A B C D A B C D 38 10 Corner A B A B 38 10 A B A B 38 UBP 10 for installation with UBP substructure panel Nordic double shell masonry clinker brick A B A B 38 C D 200 min 30 mm single shell masonry ETICS A B A B 38 C D 95 min 30 mm Requirements The wall opening Ø 180 mm is finished The cables to the wall opening of the ventilation unit have been laid Determine the exact wall thickness X D Ext...

Page 23: ...ccumulation of condensation water in the wall sleeve Damage to exterior wall and masonry and the building structure Attach the wall sleeve with a slope of 1 to 2 to the exterior wall Attach the wall sleeve inside and outside with the mounting wedges so that there is a slope of 1 2 to the exterior wall Check the angle of the wall sleeve using a spirit level NOTICE Contamination of the wall sleeve b...

Page 24: ...barrier levels Foam seal the gap between the wall sleeve and masonry all the way around with non pressing 2K polyurethane foam NOTICE Connect Undercover inner cov ers Leave a 30 mm gap behind the interior wall edge of the wall sleeve otherwise the housing can no longer be inserted Flair Flush with the interior wall Flush with the exterior wall Take care not to damage the connecting cable on the in...

Page 25: ... holes with Ø 8 mm min 50 mm deep NOTICE Installing on an unfinished exterior wall leads to damage to the exterior wall Only install the external termination once the exterior wall is finished and has fully dried NOTICE Penetration of condensation water and or algae accumulation around the external termination leads to damage to the masonry exterior wall and or discolouration of the façade Secure ...

Page 26: ... This prevents the sealing tape from swelling too much and makes installation easier From the exterior wall side attach the 9 mm seal ing tape circumferentially flush with the base plate flush with the opening for the wall sleeve with 5 mm clearance along the outer edge The sealing tape must not protrude at the inner edge of the wall sleeve opening Insert the rawl plugs into the boreholes Screw th...

Page 27: ...weather protection hood from the front into the side screws blue arrows of the base plate The washers are located between the panel and the screw Engage the panel downwards Screw the panel firmly to the base plate with the side screws firmly to the base plate Ö The Smart weather protection hood is installed ...

Page 28: ...p tape is placed in the lower area of the wall sleeve Slide the base plate onto the projecting wall sleeve The protective grid is directed towards the floor Level the base plate using a spirit level Mark the four boreholes Outer boreholes blue arrow Masonry Inner boreholes green arrow Simplex Drill the four holes with Ø 8 mm min 50 mm deep TIP Do not apply the sealing tape until immediately before...

Page 29: ...n for fixing purposes These are not included in the scope of supply they are available as an option Seal the joint between the base plate and the exterior wall with a permanently elastic exterior sealant NOTICE If the joint between the base plate and the exterior wall is incorrectly sealed the cover cannot be fitted Seal only the upper joint between the base plate and the exterior wall Place the c...

Page 30: ...tion is fitted Remove the Styrofoam disc from the wall sleeve Insert the thermal accumulator from the interior into the wall sleeve The handle points towards the interior The connecting cables protrude into the interior From the interior slide the thermal accumulator towards the external termination as far as the end stop tape Insert the inVENTron from the interior into the wall sleeve so that you...

Page 31: ...ing cable NOTICE Using the wrong wire end fer rules to connect the cables in the plug in connector will lead to a short circuit in the fan BUS Use wire ferrules with collars to connect the wire strands Press wire end ferrules onto the cables cable cross section 0 75 mm Loosen the plug connections on the reversible fans of the two ventilation units Align the plug connectors on the ventilation units...

Page 32: ...eversible fan starts in extract air mode the other in supply air mode This start direction is determined by the different connection sequence of the three fan BUS cables in the plug in connector Secure the three fan BUS cables controller connecting cables in the plug in connector Exhaust air mode White cable III in the left pole Green cable IV in the middle pole Brown cable V in the right pole Sup...

Page 33: ...n the controller cable 4 Fan BUS to controller 5 Clamping screws on the controller plug in connector 6 Clamping screws on the fan plug in connector Plug in connector on the fan cable Plug in connector cable coming from controller Start direction extract air Start direction supply air Terminal block Colour Terminal block Meaning Colour Terminal block Meaning Colour CW Blue III GND White V GND Brown...

Page 34: ...und the wall sleeve Level the inner cover base plate using a spirit level Mark the four corner drill holes Drill the four holes with Ø 6 mm min 40 mm deep The assembly of any interior termination variants is not part of this documentation It can be found in the separate installation instructions for the respective inner cover the Connect controller platform Spirit level pencil drill with 6 mm bit ...

Page 35: ...nstall the dust filter properly to avoid a malfunction of the ventilation unit Insert the dust filter into the base plate Push the filter ring firmly between the fixing tabs and the inner edge of the base plate The tab on the filter ring faces the inside and is located in the cut out provided in the base plate Place the panel on the four spacers The position arrows on the back of the inner cover p...

Page 36: ...ir incl SDE 13 35 with IB Connect Standard sound level difference dB Standard 38 49 Thermal efficiency of heat recovery η w 0 87 Input voltage V DC 6 16 Power consumption W 1 3 Specific fan power input W m h 0 15 Protection class EN 61140 III Type of protection EN 60529 IP20 Standard filter filter class ISO 16890 EN 779 2012 ISO Coarse 60 G4 Sensitivity of the air flow at 20 Pa EN 13141 8 S3 Elect...

Page 37: ...rom the product data sheet Energy efficiency class SEC class Sound power level Lwa Maximum air flow supply air Demand controlled Manually controlled MZ Home sMove with sensors Easy Connect e16 sMove without sensor technology 2016 1254 2014 45 dB A ENERGIA ЕНЕРГИЯ ΕΝΕΡΓΕΙΑ ENERGIJA ENERGY ENERGIE ENERGI A A A A A A A B C D E F G iV Smart iV Smart Corner iV Smart Nordic iV Smart Top iV Smart Sylt 58...

Page 38: ...stem Regenerative g Degree of temperature change ƞt 87 h Maximum air flow rate m h 58 i Electrical input power incl control W 6 j Sound power level Lwa dB A 45 k Reference air flow m h 42 l Reference pressure difference Pa 0 m SEL W m h 0 15 n Control factor 0 65 o Internal and external transfer n a p Mixing quota n a q Position and description of the indicator for filter change Control unit r Ins...

Page 39: ...emperature change ƞt 87 h Maximum air flow rate m h 58 i Electrical input power incl control W 6 j Sound power level Lwa dB A 45 k Reference air flow m h 42 l Reference pressure difference Pa 0 m SEL W m h 0 15 n Control factor 1 o Internal and external transfer n a p Mixing quota n a q Position and description of the indicator for filter change Control unit r Instructions regarding controllable s...

Page 40: ...our 1508 0068 Flex weather protection hood white RAL 9016 1508 0157 1508 01711 Flex weather protection hood grey RAL 9006 1508 0158 1508 01721 Flex weather protection hood Nord RAL 7011 1508 0159 Flex weather protection hood anthracite RAL 7016 1508 0160 1508 01731 Flex weather protection hood custom colour 1508 0161 1508 01741 Wall sleeve with Styrofoam discs and mounting wedges Wall sleeve R D16...

Page 41: ...an in supply air mode The rotational speed of the fan is too low Increase the output level Noises Foreign body in the fan Remove foreign body from the fan Clean the ventilation unit Thermal accumulator is not correctly positioned in the wall sleeve Slide the thermal accumulator out of the wall sleeve Insert it again Slide the thermal accumulator into the wall sleeve as far as the end stop tape The...

Page 42: ...out the warranty is available at www inventer de garantie 9 Service Claims Check the delivery for completeness and transport damage upon receipt using the delivery note Report missing items immediately and at the latest within 14 days to your supplier distributor or factory representative Warranty and guarantee claims In the case of a warranty or guarantee claim contact your local distributor or f...

Page 43: ...43 WARRANTY AND GUARANTEE 43 iV Smart ventilation unit Installation instructions NOTES ...

Page 44: ...Item number 5001 0038 Version 1 1 07 2021 Subject to modifications We accept no liability for printing errors inVENTer GmbH Ortsstraße 4a D 07751 Löberschütz Germany www inventer de ...

Reviews: