USER AND SAFETY INSTRUCTIONS
USER AND SAFETY INSTRUCTIONS
Ventilation System iV-Twin+
•
Installation and Operating Instructions
Ventilation System iV-Twin+
•
Installation and Operating Instructions
1
User and Safety Instructions
Thank you for choosing a inVENTer quality product!
This chapter will provide you with an overview of the basic safety precautions for safe and
proper operation of your ventilation system.
1.1
User information
Safety and warning concept
The safety and warning notices in these mounting and operating instructions are uniformly
structured and marked with a symbol on the left-hand side of the notice.
A signal word in front of the text indicates the hazard level. When multiple hazard levels occur,
the safety information for the highest level is always used.
The safety notes and warnings contain the following information:
SIGNAL WORD:
Type and origin of the danger
Possible consequences of the danger!
• Measures to avoid the danger.
The signal word indicates the severity of the danger that occurs if it is not avoided:
WARNING
means: Serious personal injury or death may be imminent.
CAUTION
means: There is an immediate danger of slight/moderate personal injury.
NOTE
means: Property damage due to an undesirable event or condition is imminent or
possible.
If you see these signs, observe the measures described to avoid possible risks and damage.
Additional Symbols in the Documentation
In addition to the safety and warning instructions, the following symbols are used:
A
TIP
symbol provides practical and useful tips on how to handle your Ventilation
system.
Prior the action sequences, additional tools and aids for the activities involved are
enumerated if required.
Red bar
on top of a graphic: Figure shows the inner wall.
Blue bar
on top of a graphic: Figure shows the outer wall.
►
Instruction:
Prompts the operator to take action.
Action result:
Prompts to check the result of the actions.
1.2
Safety instructions
The installation and operating instructions are an integral part of your ventilation system and
must always available. When the device/system is handed over to a third party, the installation
and operating instructions must also be handed over. Before carrying out any work on the
device/system, read the installation and operating instructions carefully and observe all the
instructions for installation, operation, cleaning and maintenance given in this chapter. In
addition, observe the safety instructions that precede the instructions described. Failure to
comply with safety regulations can lead to personal injury and/or damage to property.
Intended use
The ventilation unit is used for the ventilation of living spaces and similar residential spaces.
They are controlled by a controller of the inVENTer system.
General information
• When installing the device/system, observe the applicable standards, regulations and
directives. In particular, the applicable building regulations, fire protection regulations and
accident prevention regulations of the employers' liability insurance association.
• Only use the device/system in accordance with the applications described in this
documentation and only in conjunction with the components supplied, recommended,
approved by the inVENTer GmbH, and mentioned in this documentation.
Modifications or alterations to the device/system are not permitted.
• Your ventilation system has been designed exclusively for use in ambient temperatures within
-20 – 50 °C.
• Proper and safe operation of the device/system requires proper transport, proper storage and
installation as well as careful operation and cleaning/maintenance.
Installation and installation
• CAUTION:
The system may only be installed by qualified personnel.
• Before starting the work, you should have at hand a project plan which shows the number of
ventilation units, the position of the ventilation units, the ventilation principle (cross ventilation,
single room ventilation, exhaust ventilation) and the corresponding controllers. The exact
positioning of the individual devices and control units must be checked by the customer and,
if necessary, adapted to the local conditions with the involvement of the responsible planner
or the user. For optimum functionality, it is recommended that the unit be installed at an
appropriate location in the upper wall area.
• WARNING:
For joint operation with room air-dependent and not room air-independent
fireplaces, safety measures must be taken to prevent the creation of negative pressure in the
building. The responsible chimney sweep and/or building planner decides which measures
are to be taken.
• NOTE:
The ventilation unit is not suitable for drying out buildings. Do not put it into
operation until the construction work has been completed. Seal the ventilation unit
dust-tight during the entire construction work Styrofoam disks enclosed).
• NOTE: Contamination of components by e.g. plaster residues leads to damage of the
components! Close the ventilation unit/air outlets of the ventilation unit dust-tight during the
entire construction work. Do not remove thread locks until final mounting.
• NOTE:
Do not install the unit near room air thermostats or in the immediate surroundings/
above sensitive pictures or furniture.