SYSTEM OVERVIEW: MZ-HOME CONTROLLER
7
MZ-Home | Operating instructions
2.1 Construction
The MZ-Home controller consists of a programming unit and at least one up to a maximum of 4
Clust-Air module(s).
Operating unit
The operating unit is installed on the interior wall. It serves as an operating and display interface
for the user.
Figure 1: MZ-Home operating unit front view
Clust-Air module
®
CAM17
In addition to the operating unit, one Clust-Air module is
installed per ventilation area (zone). This contains the
electronics for the zone to be controlled and is mounted
in it. After installation, it is covered with a switch design
cover or wallpapered over so that it is no longer visible.
The Clust-Air modules make it possible to divide the accommodation unit individually into different
ventilation areas (zones). Each Clust-Air module is assigned to a zone and can be controlled
separately. A Clust-Air module enables the control of up to four inVENTer
®
ventilation devices with
heat recovery and the connection of another external sensor (digital or analogue).
The Clust-Air module contains a humidity and temperature sensor. It is installed in separate
housing in the room air flow and connected to the Clust-Air module for the appropriate zone. The
relative humidity of the zone is continuously measured by the humidity and temperature sensor
for each Clust-Air module. The controller is thus capable of automatically switching to dehumid-
ification mode and back again when the relative room air humidity crosses specified limits. This
ensures a healthy indoor climate that suits your needs is reached without requiring manual input.