23
ASSEMBLY AND INSTALLATION
inVENTer PAX standard set
•
Installation and operating instructions
TIP:
Three cable conduits are located on the back of the main module for different ways of
laying the power cable to the unit's electrical connection.
CAUTION
Falling main module.
Injury to persons and/or damage to property!
►
Screw the main module to the mounting plate.
NOTICE
Displacement of the Folded spiral-seam ducts in the wall duct.
Leakage airfl ow and/or condensate penetration into insulating sleeves!
►
Fix the folded spiral-seam ducts by applying counter pressure from the outside.
Ö
The main module is installed.
►
Lay the power cable inside one of the cable
conduits.
►
Affix the power cable inside the selected cable
conduit with adhesive tape.
►
Seal the cable entry (red arrow) with perma-
nently elastic sealing compound.
►
Press the main module against the mounting
plate.
►
Push the main module towards the wall duct.
►
Snap the catch on the mounting plate into
place in the corresponding slot on the main
module’s base.
1
2
►
Screw the main module to the mounting plate
with 4 screws using the supplied 200 mm bit
PH2.