10
Pulsar extractor fan
•
Installation and operating instructions
4
Electrical connection
The Pulsar extractor fan can be connected directly to the 230 V AC mains
or
can be operated with 12 V DC (SELV). A power supply unit is available as an option.
NOTICE
Simultaneous connection of 230 V AC and 12 V DC.
Damage to the Pulsar extractor fan!
►
Never simultaneously connect the Pulsar extractor fan to 230 V AC and 12 V DC.
4.1 Electrical connection AC 100 – 240 V (Alternating current)
DANGER
Exposed electrical components.
Electric shock and injury due to live components (230 V, 50 Hz)!
►
Before working on electrical installations, disconnect all affected equipment from the power supply.
►
Do not lay or connect live cables.
►
The connection must only be performed by qualified and trained personnel.
DANGER
Ingress of water into the Pulsar extractor fan or its components/power source.
Electric shock and overheating due to short circuit (230V, 50Hz)!
►
Install Pulsar outside protection area 0.
►
Install Pulsar’s power source outside protection area 2.
NOTICE
Insufficient wire cross-section.
Excessive voltage drop and/or contact cannot be guaranteed!
►
For the power cable (mains cable) use a wire cross-section of 1.5 mm².
NOTICE
Power cable routed over PCB cover.
Damage to the PCB and no function of the Pulsar extractor fan!
►
Do not route the 100 – 240 V AC power cable over the PCB.
ELECTRICAL CONNECTION
ELECTRICAL CONNECTION