12
Pulsar extractor fan
•
Installation and operating instructions
1 Sensor-controlled, with continuous ventilation:
• This setting must be selected via the inVENTer Mobile app.
• Continuous ventilation with a flow rate of 30 m³/h.
• Increases the fan power with elevated humidity or due to lighting changes.
2 Sensor-controlled, without continuos ventilation:
• Factory setting to ensure ventilation as required.
• The extractor fan is switched on and off automatically when the humidity or lighting changes.
3 Use as a wall-vent fan
• This setting must be selected via the inVENTer Mobile app.
• Suitable for ventilation of adjacent rooms.
• The extractor fan is switched on/off based on the temperature, the light and humidity sensors are inactive.
4 Switch-controlled, without run-on function:
• This setting must be selected via the inVENTer Mobile app.
• The extractor fan is switched on and off by means of a manual, external S switch.
• The sensors are deactivated.
• When the fan is switched off at the external S switch, the fan switches off immediately.
5 Switch-controlled, with run-on function:
• This setting must be selected via the inVENTer Mobile app.
• The extractor fan is switched on and off by means of a manual, external S switch.
• The sensors are deactivated.
• When the fan is switched off at the external S switch, the fan runs for the set run-on time and then switches off
automatically.