background image

Record: 0 – reset reading flag 

20

1005

Single Coil

R/W

Status reset 
Reading: 1 – there was a restart of the reader (ex. 
through power failure)
Record: 1 – forcing a device reset
0 –  Restart flag reset

21

1006

Single Coil

R/W

Safety status
Reading: 1 – Has been Safety mode triggered
Record: 0 –  Flag reset

22

1007

Single Coil

R/W

RS485 status
Reading: 1 – Has beenTimeout of communication 
RS485
Record 0 – Flag reset

23

1008

Single Coil

R

Input mode
Reading: 1 – active input, 0 – inactive input 
(OPTION)

In case of no recording of new event of transponder code reading in Holding Register 1000-

1004   appear random data. Correct number  shows only in  the moment of reading new event,
indicated by setting the registry Single Coil 1004 (1- read a new transponder). The next reading of
the transponder is only possible after resetting the reading flag and entered „zero” into the 1004
register 
Changing the output parameters for MODBUS, is not stored in it is stored in module volatile
memory. It means that after the restart or turn into the Safety mode there will be restored output
parameters previously writing to the EEPROM via USB.
Triggered of the Safety mode  restores output settings stored in the EEPROM. It means that times of
switching on, of and output mode are overwritten.   After exit Safety mode, if it's demanded all
output parameters should be set again by MODBUS

Summary of Contents for RFID-MB-10

Page 1: ...User manual RFID MODBUS Reader RFID MB 10 INVEO s c ul Rzemie lnicza 21 43 340 Kozy tel 48 785552252 www inveo com pl info inveo com pl...

Page 2: ...priate ways of dealing with this device the basic principles of safety and maintenance Please also keep the user manual so that you can read it during later use Remember The manufacturer is not liable...

Page 3: ...ILISATION OF THE MODULEA 5 4 CONSTRUCTION EQUIPMENT 6 4 1 GENERAL FEATURES 6 5 DEVICE CONFIGURATION 7 5 1 OUT MODE 7 5 2 OUTPUT CONTROL OUT STATE TEST 8 5 3 READING CARD NUMBER CARD SERIAL NUMBER 8 5...

Page 4: ...ct of guarantee if the following conditions are met all repairs alterations extensions and device calibrations are performed by the manufacturer or authorized service supply network installation meets...

Page 5: ...midity from 30 to 75 atmospheric pressure is in the range 700 1060hPa Recommended conditions for transportation temperature from 10 C to 45 C humidity from 20 to 95 atmospheric pressure is in the rang...

Page 6: ...15mA 12V Transponders Supported transponders UNIQUE Carrier frequency 125kHz Coding Manchester Reading distance 10cm Communication 1 port compatible with RS485 USB port for configuration Support MODBU...

Page 7: ...ot required the device is fed through the USB port Drawing 1 Aplication window 5 1 OUT mode Mode Set the output mode selected from Static bistable mode Toggle momentary mode alternately turning on and...

Page 8: ...hows the last read transponder code 5 4 RS485 Configuration of transmission RS485 The field is used to configure the device communication MODE setting 9 bit transmission None Odd Even Mark bit 1 the s...

Page 9: ...R Software version 8 1007 Holding Reg R Hardware version 9 1008 Holding Reg R Output state after switching and in Safety mode 10 1009 Holding Reg R Time of communication failure followed by a transit...

Page 10: ...04 appear random data Correct number shows only in the moment of reading new event indicated by setting the registry Single Coil 1004 1 read a new transponder The next reading of the transponder is on...

Page 11: ...elay output max 1 A when 30 VDC max 0 5 A when 125 VAC RS485 Communication port Power LED LED indicates power connection to the module Status LED LED indicates operation of the relay USB USB port modu...

Page 12: ...Notes...

Page 13: ......

Reviews: