ELECTRICAL INSTALLATION
Electrical Interface
The Optipad uses a standard RJ45 8-Way connector as its electrical
interface, which provides a simple solution for the user to setup
their system using a standard RJ45 8-Way data cable. The signal
layout of the connector is as follows:
Cable Requirements
Standard 8-way data cables with plugs are available from your local
Invertek Drives stockist on request.
If the data cable is made up on site, ensure that the connection pin
out is correct: Pin 1 to Pin 1, through Pin 8 to Pin 8.
CAUTION
Incorrect cable connection may damage the drive. Extra care should
be taken when using third party cable.
System Setup
The Optidrive provides the +24V power supply to the Optipad via
the RJ45 connection. Once the physical connection has been setup,
the system is ready to operate. See picture below:
Note: The location of the RJ45 connector on the Optidrive will vary
depending on the Optidrive range and model.
RJ45 Port
MECHANICAL INSTALLATION
DIMENSIONS
THROUGH PANEL MOUNT
The panel on to which the Optipad is to be mounted should be cut
out in accordance with the diagram below.
SAFETY
Optipad is designed to be used in conjunction with the Optidrive
variable speed drive ranges listed. It is intended for professional
incorporation into complete equipment or systems. The Optipad can
be used to control the operation of the Optidrive ranges ODE-2, ODP-
2 and ODV-2 (hereafter referred to as Optidrive). The drive must be
installed correctly to prevent a safety hazard. The Optidrive uses high
voltages and currents, carries a high level of stored electrical energy,
and is used to control mechanical plant that may cause injury. Close
attention is required to system design and electrical installation to
avoid hazards in either normal operation or in the event of
equipment malfunction.
System design, installation, commissioning and maintenance must be
carried out only by personnel who have the necessary training and
experience. They must read carefully this safety information and the
instructions in this and the Optidrive User Guides and follow all
information regarding transport, storage, installation and use,
including the specified environmental limitations.
Please read the
IMPORTANT SAFETY INFORMATION
below, and all
Warning and Caution boxes within this document.
SAFETY NOTICES
WARNING
is given where there is a hazard that could lead to injury
or death of personnel.
CAUTION
is given where there is a hazard that could lead to damage
to equipment
.
Dr David Jones, R&D Director
DECLARATION
All rights reserved. No part of this User Guide may be reproduced or
transmitted in any form or by any means, electrical or mechanical
including photocopying, recording or by any information storage or
retrieval system without permission in writing from the publisher.
Copyright Invertek Drives Ltd © 2012
The manufacturer accepts no liability for any consequences resulting
from inappropriate, negligent or incorrect installation, or adjustment
of the optional operating parameters of the drive or from
mismatching of the drive to the motor.
The contents of this User Guide are believed to be correct at the time
of printing. In the interests of a commitment to a policy of
continuous improvement, the manufacturer reserves the right to
change the specification of the product or its performance or the
contents of the User Guide without notice.
WARRANTY
All Invertek Drives Ltd (IDL) products carry a 2-year warranty, valid
from the date of manufacture.
Complete Warranty Terms and Conditions are available upon request
to your IDL Authorized Distributor.
INVERTEK DRIVES LTD
Offa’s Dyke Business park
Welshpool
Powys
SY21 8JF
UK
Tel +44 (0) 1938 556868
Fax +44 (0) 1938 556869
Internet www.invertek.co.uk
Part No. 82-OPT-2-OPPAD-IN
V 1.00 July 2012
O
PTIPAD
OLED Remote Keypad Option Module
User Guide
Installation and Operating Instructions
IMPORTANT SAFETY INFORMATION
Safety of machinery, and safety-critical applications
The level of integrity offered by the Optipad / Optidrive control
functions – for example stop/start, forward/reverse and maximum
speed, is not sufficient for use in safety-critical applications without
independent means of protection. All applications where
malfunction could cause injury or loss of life must be subject to a risk
assessment and further protection provided where needed.
Within the European Union, all machinery in which this product is
used must comply with Directive 98/37/EC, Safety of Machinery. In
particular, the electrical equipment should comply with EN60204-1.
GENERAL SPECIFICATION
Compatible Drives:
Optidrive ODE-2, ODP-2, and ODV-2
Signal Interface:
Standard 8-way RJ45 connector
Supply Input:
24V + / - 10%, DC, 30mA
RS485 signal:
Industry standard 2-wire +5V differential
Environmental:
Operational:
-10 … 50
C
Storage:
-40
C … 60
C
Relative Humidity
< 95% (non condensing)
Protection rating:
IP54
Max cable length:
25m / 82.5ft shielded twisted pair
WARNING
When installing the Optipad, all Optidrives should be disconnected
and
ISOLATED
before attempting any work. High voltages are
present at the terminals and within the drive for up to 10 minutes
after disconnection of the electrical supply. The Optidrives should
be installed by qualified electrical persons and in accordance with
local and national regulations and codes of practice.
Refer to the relevant Optidrive user manual for further details.
CAUTION
Carefully inspect the Optipad before installation to ensure it is
undamaged.
Store the Optipad in its box until required. Storage should be clean
and dry. Temperature range -40
o
C to +60
o
C.
Install the Optipad on a flat, flame-resistant vibration-free surface.
Flammable material should not be placed close to the Optipad.
RJ45 Interface Signal Layout
NC
NC
0V
RS485 - / Optibus
RS485 + / Optibus
+24V
NC
NC
Optidrive
1
1
Invertek Drives Ltd adopts a policy of continuous improvement and
whilst every effort has been made to provide accurate and up to
date information, the information contained in this User Guide
should be used for guidance purposes only and does not form the
part of any contract.