Secureuro Plus – User manual
EN
Página 21
6.2. Detection error codes display
If one of the following error codes is displayed on the display
Windows during the course of detection, you can handle
them as per the error type after the device is stopped.
Error codes list during the detection.
Error message
display
Error type
E01
Paper length error.
E02 / E03
Magnetic feature error.
E04 / E05
IR (infrared) feature error.
E06
Paper thickness error.
E07
Slant Banknote error.
E08
Hologram error.
E09 / E10 / E11 / E12
Paper quality error.
E20
Banknote passing error.
6.3. Important notices.
If the machine keeps alarm or Works abnormally, check the
following:
•
Whether the main power supply is within specified range
(AC 100V-240V / 50-60Hz).
•
Whether the DC output is within specified range: DC
5V+/- 5%
•
Whether the supply plug is well connected.
•
Whether the built-in battery is sufficient to work.
•
Keep away from strong magnetic affection.