To ensure better contact and reliability, ring terminal shall be fit on the cables from
PV string before connecting to the inverter. The recommended size of ring terminal
is
Model
Wire Gauge
Ring Terminal
Cable mm
²
Dimensions
D(mm)
L(mm)
1K/1.2K/2K/2.2K
1*10AWG
5.16
5.3
19.8
Connect the cables from PV string to PV input terminals as shown below, a circuit
breaker with 80A rating shall be installed as shown below, please check the polarity
before connection.
Circuit
Breaker
2.5 Connect AC Input Cables and Loads
Connect the AC input cables and loads to the receptacles as shown below.
2.6 AC Input Voltage Range Selector
A. “
NARROW" setting:
Set the selector to "NARROW" when connected with loads which are more sensitive
on voltage range. With this setting, the inverter is more sensitive to the voltage
disturbance on the AC input and the input voltage range is set at 170~280VAC while
output voltage follows input voltage.