Goodrive18 series two-in-one VFD Operating
-24-
frequency, bus voltage, input terminal status, output terminal status, PID reference value, PID
feedback value, torque setting, AI2, AI3, PLC and the current step of multi-step speed, pulse
counting value, and length value. You can press >>/SHIFT to shift selected parameters from
left to right or press QUICK/JOG (
=2) to shift selected parameters from right to left.
4.2.2 Displaying running-state parameters
After receiving a valid running command, the VFD enters the running state, and the keypad
display running-state parameters, with the RUN/TUNE indicator on. The on/off state of the
FWD/REV indicator is determined by the current running direction.
In running state, there are 24 parameters that can be selected for display, including running
frequency, set frequency, bus voltage, output voltage, output current, running speed, output
power, output torque, PID reference value, PID feedback value, input terminal status, output
terminal status, torque setting, length value, PLC and the current step of multi-step speed, AI2,
AI3, motor overload percentage, VFD overload percentage, ramp reference value, linear
speed, and AC input current. You can determine which parameters are displayed by setting
You can press >>/SHIFT to shift selected parameters
from left to right or press QUICK/JOG (
=2) to shift selected parameters from right to
left.
4.2.3 Displaying fault information
After detecting a fault signal, the VFD enters the fault alarm state immediately, the fault code
blinks on the keypad, and the TRIP indicator is on. You can perform fault reset by using the
STOP/RST key, control terminals, or communication commands.
If the fault persists, the fault code is continuously displayed.
4.2.4 Editing function codes
You can press the PRG/ESC key to enter the editing mode in stopped, running, or fault alarm
state (if a user password is used, see the description of
). The editing mode contains
two levels of menus in the following sequence: Function code group or function code number
→
Function parameter. You can press the DATA/ENT key to enter the function parameter
display interface. On the function parameter display interface, you can press the DATA/ENT
key to save parameter settings or press the PRG/ESC key to exit the parameter display
interface.
RUN/TUNE
FWD/REV
LOCAL/REMOT
Hz
TRIP
A
V
RPM
%
RUN/TUNE
FWD/REV
LOCAL/REMOT
TRIP
Hz
A
V
RUN/TUNE
FWD/REV LOCAL/REMOT
TRIP
Hz
A
V
RPM
%
RPM
%
Figure 4.3 Status display