Goodrive18 series two-in-one VFD Function parameters and function terminal reuse
-81-
Function
code
Name
Description
Default
value
Modify
source A frequency is invalid
1: A+B frequency, buffering
acceleration/deceleration of main reference
source A frequency is valid and the
acceleration/deceleration is determined by
P09.14
Reserved
0.00
–100.00
1.00
○
P09.15
PID command
ACC/DEC time
0.0
–1000.0s
0.0s
○
P09.16
PID output filter
time
0.000
–10.000s
0.000s
○
P09.17
Low frequency
proportional
gain (Kp)
0.00
–100.00
1.00
○
P09.18
Low frequency
integral time (Ti)
0.00
–10.00s
0.10s
○
P09.19
Low frequency
differential time
(Td)
0.00
–10.00s
0.00s
○
P09.20
Low point
frequency of
PID parameter
switching
0.00Hz
When the ramp frequency is no greater than
. When the ramp frequency is no less
than
, current PID parameters are
. The medium frequency range is
the linear interpolation values between the two
PID parameter groups.
5.00Hz
○
P09.21
High point
frequency of
PID parameter
switching
10.00Hz
○
P10 Simple PLC and multi-step speed control
P10.00
Simple PLC
mode
0: Stop after running once. The VFD has to be
commanded again after finishing a cycle.
1: Run at the final value after running once. After
finishing a cycle, the VFD will keep the running
frequency and direction of the last run.
0
○
Summary of Contents for GD18-004-4-2
Page 1: ......