Goodrive200 inverters Function codes
101
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P08.12
Jumping
frequency
range 2
Setting range: 0.00Hz ~P00.03
(the Max. frequency)
0.00Hz
○
P08.13
Jumping
frequency
3
0.00Hz
○
P08.14
Jumping
frequency
range 3
0.00Hz
○
P08.15
Traverse
range
This function applies to the industries where
traverse and convolution function are required
such as textile and chemical fiber.
The traverse function means that the output
frequency of the inverter is fluctuated with the set
frequency as its center. The route of the running
frequency is illustrated as below, of which the
traverse is set by P08.15 and when P08.15 is set
as 0, the traverse is 0 with no function.
Traverse range: The traverse running is limited
by upper and low frequency.
The traverse range relative to the center
frequency: traverse range AW
=
center frequency
×
traverse range P08.15.
Sudden jumping frequency
=
traverse range AW
×
sudden jumping frequency range P08.16.
When run at the traverse frequency, the value
0.0%
○
P08.16
Sudden
jumping
frequency
range
0.0%
○
P08.17
Traverse
boost time
5.0s
○
P08.18
Traverse
declining
time
5.0s
○
Summary of Contents for GD200-037G/045P-4
Page 1: ...Goodrive 200 Inverter ...
Page 44: ...Goodrive200 inverters Keypad operation procedure 43 Fig 5 5 Sketch map of state watching ...
Page 158: ...Goodrive200 inverters Basic operation instruction 157 ...
Page 208: ...Goodrive200 inverters Fault tracking 207 8 6 2 Motor vibration 8 6 3 Overvoltage ...
Page 209: ...Goodrive200 inverters Fault tracking 208 8 6 4 Undervoltage fault 8 6 5 Inverter overheating ...
Page 210: ...Goodrive200 inverters Fault tracking 209 8 6 6 Abnormal motor heat ...
Page 211: ...Goodrive200 inverters Fault tracking 210 8 6 7 Stall during the acceleration of the motor ...
Page 266: ...1 1 0 0 1 0 0 7 7 9 6 6 0 0 1 0 0 0 9 5 201701 V2 2 ...