Goodrive200
inverters Basic operation instruction
181
PLC finishes a circle (or a step).
Relative parameters list:
Function
code
Name
Detailed instruction of parameters
Default
value
P10.00
Simple PLC
0:Stop after running once
1:Run at the final value after running
once
2:Cycle running
0
P10.01
Simple PLC memory
0:Power loss without memory
1:Power loss memory
0
P10.02
Multi-step speed 0
-100.0~100.0%
0.0%
P10.03
The running time of step
0
0.0~6553.5s(min)
0.0s
P10.04
Multi-step speed 1
-100.0~100.0%
0.0%
P10.05
The running time of step 1 0.0~6553.5s(min)
0.0s
P10.06
Multi-step speed 2
-100.0~100.0%
0.0%
P10.07
The running time of step 2 0.0~6553.5s
(
min
)
0.0s
P10.08
Multi-step speed 3
-100.0~100.0%
0.0%
P10.09
The running time of step 3 0.0~6553.5s(min)
0.0s