Goodrive200 inverters Appendix C
259
C.7.2 Filters selection table
The inverter
Input filter
Output filter
GD200-1R5G-4
FLT-P04006L-B
FLT-L04006L-B
GD200-2R2G-4
GD200-004G/5R5P-4
FLT-P04016L-B
FLT-L04016L-B
GD200-5R5G/7R5P-4
GD200-7R5G/011P-4
FLT-P04032L-B
FLT-L04032L-B
GD200-011G/015P-4
GD200-015G/018P-4
FLT-P04045L-B
FLT-L04045L-B
GD200-018G/022P-4
GD200-022G/030P-4
FLT-P04065L-B
FLT-L04065L-B
GD200-030G/037P-4
GD200-037G/045P-4
FLT-P04100L-B
FLT-L04100L-B
GD200-045G/055P-4
GD200-055G/075P-4
FLT-P04150L-B
FLT-L04150L-B
GD200-075G/090P-4
GD200-090G/110P-4
FLT-P04240L-B
FLT-L04240L-B
GD200-110G/132P-4
GD200-132G/160P-4
GD200-160G/185P-4
FLT-P04400L-B
FLT-L04400L-B
GD200-185G/200P-4
GD200-200G/220P-4
GD200-220G/250P-4
FLT-P04600L-B
FLT-L04600L-B
GD200-250G/280P-4
GD200-280G/315P-4
GD200-315G/350P-4
FLT-P04800L-B
FLT-L04800L-B
GD200-350G/400P-4
GD200-400G-4
GD200-500G-4
FLT-P041000L-B
FLT-L041000L-B
Note:
The input EMI meet the requirement of C2 after adding input filters.
C.8 Braking system
C.8.1 Select the braking components
It is appropriate to use braking resistor or braking unit when the motor brakes sharply or the
motor is driven by a high inertia load. The motor will become a generator if its actual rotating
Summary of Contents for GD200-037G/045P-4
Page 1: ...Goodrive 200 Inverter ...
Page 44: ...Goodrive200 inverters Keypad operation procedure 43 Fig 5 5 Sketch map of state watching ...
Page 158: ...Goodrive200 inverters Basic operation instruction 157 ...
Page 208: ...Goodrive200 inverters Fault tracking 207 8 6 2 Motor vibration 8 6 3 Overvoltage ...
Page 209: ...Goodrive200 inverters Fault tracking 208 8 6 4 Undervoltage fault 8 6 5 Inverter overheating ...
Page 210: ...Goodrive200 inverters Fault tracking 209 8 6 6 Abnormal motor heat ...
Page 211: ...Goodrive200 inverters Fault tracking 210 8 6 7 Stall during the acceleration of the motor ...
Page 266: ...1 1 0 0 1 0 0 7 7 9 6 6 0 0 1 0 0 0 9 5 201701 V2 2 ...