Goodrive350 series high-performance multifunction VFD
Function parameter list
-190-
Function
code
Name
Description
Default
value
Modify
700.0V;
660V
voltage:
1120.0V
P08.39
Running mode of
cooling fan
0: Common running mode
1: The fan keeps running after power-on
2: Running mode 2
0
○
P08.40
PWM selection
0x0000
–0x1121
Ones place: PWM mode selection
0: PWM mode 1, 3PH modulation and 2PH
modulation
1: PWM mode 2, 3PH modulation
Tens place: PWM low-speed carrier limit
0: Low-speed carrier limit mode 1
1: Low-speed carrier limit mode 2
2: No limit
Hundreds place: Deadzone compensation method
0: Compensation method 1
1: Compensation method 2
Thousands place: PWM loading mode selection
0: Interruptive loading
1: Normal loading
0x1101
◎
P08.41
Overmodulation
selection
0x0000
–0x1111
Ones place: Whether to enable overmodulation
0: Disable overmodulation
1: Enable overmodulation
Tens place: Overmodulation mode
0: Mild overmodulation
1: Deepened overmodulation
Hundreds: Carrier frequency limit
0: Yes
1: No
Thousands: Output voltage compensation
0: No
1: Yes
0x1001
◎
P08.42 Reserved
/
/
/
P08.43 Reserved
/
/
/
P08.44
UP/DOWN
0x000
–0x221
0x000
○