Goodrive350 series high-performance multifunction VFD
Function parameter list
-230-
Function
code
Name
Description
Default
value
Modify
compensation of
synchronous
motor
motor
Range: -180.0
–180.0
P17.31
High-frequency
superposition
current of
synchronous
motor
0.0%
–200.0% (of the motor rated current)
0.0%
●
P17.32 Motor flux linkage 0.0%
–200.0%
0.0%
●
P17.33
Exciting current
reference
Display the exciting current reference value under
vector control mode
Range: -3000.0
–3000.0A
0.0A
●
P17.34
Torque current
reference
Display torque current reference value under
vector control mode
Range: -3000.0
–3000.0A
0.0A
●
P17.35
AC incoming
current
Display the valid value of incoming current on AC
side
Range: 0.0
–5000.0A
0.0A
●
P17.36
Output torque
Display output torque value, during forward
running, positive value is motoring state, negative
value is generating state; during reverse running,
positive value is generating state, negative value is
motoring state.
Range: -3000.0Nm
–3000.0Nm
0.0Nm
●
P17.37
Motor overload
count value
0
–65535
0
●
P17.38
Process PID
output
-100.0%
–100.0%
0.00%
●
P17.39
Parameter
download wrong
function code
0.00
–99.00
0.00
●
P17.40
Motor control
mode
0x000
–0x123
Ones: Control mode
0: Vector 0
1: Vector 1
2: VF control
3: Closed-loop vector control
Tens: Control state
0x000
●