Goodrive350 series high-performance multifunction VFD
Function parameter list
-260-
Function
code
Name
Description
Default
value
Modify
P26.10
Relay RO9
output selection
0
○
P26.11
Relay RO10
output selection
0
○
P26.12
Output terminal
polarity of
expansion card
0x0000
–0x1FFF
Bit0: Y2
Bit1: Y3
Bit2: HDO2
Bit3: RO3
Bit4: RO4
Bit5: RO5
Bit6: RO6
Bit7: RO7
Bit8: RO8
Bit9: RO9
Bit10: RO10
Bit11: RO11
Bit12: RO12
0x0000
○
P26.13
HDO2 switch-on
delay
Used to define the corresponding delay of the level
variation from switch-on to switch-off.
Y electric level
Y valid
Invalid
Switch on
delay
invalid
Valid
Switch off
delay
Setting range: 0.000
–50.000s
Note: P26.13 and P26.14 are valid only when
P26.00 is set to 1.
0.000s
○
P26.14
HDO2 switch-off
delay
0.000s
○
P26.15
Y2 switch-on
delay
0.000s
○
P26.16
Y2 switch-off
delay
0.000s
○
P26.17
Y3 switch-on
delay
0.000s
○
P26.18
Y3 switch-off
delay
0.000s
○
P26.19
Relay RO3
switch-on delay
0.000s
○
P26.20
Relay RO3
switch-off delay
0.000s
○
P26.21
Relay RO4
switch-on delay
0.000s
○
P26.22
Relay RO4
switch-off delay
0.000s
○