Goodrive350 IP55 High-ingress Protection Series VFD
Basic Operation Instructions
-99-
P10.02 multi-step speed 0
P10.03 running time of 0
th
step
P10.04 multi-step speed 1
P10.05 running time of 1
st
step
P10.06 multi-step speed 2
P10.07 running time of 2
nd
step
P10.08 multi-step speed 3
P10.09 running time of 3
rd
step
P10.10 multi-step speed 4
P10.11 running time of 4
th
step
P10.12 multi-step speed 5
P10.13 running time of 5
th
step
P10.14 multi-step speed 6
P10.15 running time of 6
th
step
P10.16 multi-step speed 7
P10.17 running time of 7
th
step
P10.18 multi-step speed 8
P10.19 running time of 8
th
step
P10.20 multi-step speed 9
P10.21 running time of 9
th
step
P10.22 multi-step speed 10
P10.23 running time of 10
th
step
P10.24 multi-step speed 11
P10.25 running time of 11
th
step
P10.26 multi-step speed 12
P10.27 running time of 12
th
step
P10.28 multi-step speed 13
P10.29 running time of 13
th
step
P10.30 multi-step speed 14
P10.31 running time of 14
th
step
P10.32 multi-step speed 15
P10.33 running time of 15
th
step
BIT0
BIT1
BIT2
BIT3
BIT4
BIT5
BIT6
BIT7
BIT8
BIT9
BIT10
BIT11
BIT12
BIT13
BIT14
BIT15
Terminal function 16
Multi-step speed
terminal 1
Terminal function 17
Multi-step speed
terminal 2
Terminal function 18
Multi-step speed
terminal 3
Terminal function 19
Multi-step speed
terminal 4
P10.34
Acceleration/deceleration time
selection of 0
–
7 section of
simple PLC
P00.11 acceleration time 1
P00.12 deceleration time 1
P08.00 acceleration time 2
P08.01 deceleration time 2
P08.02 acceleration time 3
P08.03 deceleration time 3
P08.04 acceleration time 4
P08.05 deceleration time 4
00
01
10
11
BIT0
BIT1
BIT2
BIT3
BIT4
BIT5
BIT6
BIT7
BIT8
BIT9
BIT10
BIT11
BIT12
BIT13
BIT14
BIT15
P00.10 acceleration time 1
P00.12 deceleration time 1
P08.00 acceleration time 2
P08.01 deceleration time 2
P08.02 acceleration time 3
P08.03 deceleration time 3
P08.04 acceleration time 4
P08.15 deceleration time 4
00
01
10
11
P10.35
Acceleration/deceleration time
selection of 8
–
15 section of
simple PLC
Multi-step speed
output
Running command
Multi-step speed 0
Multi-step speed 1
Multi-step speed 15
ON
OFF
OFF
ON
Terminal function 16
Multi-step speed
terminal 1
Terminal function 17
Multi-step speed
terminal 2
Terminal function 18
Multi-step speed
terminal 3
Terminal function 19
Multi-step speed
terminal 4
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Multi-step speed
8
9
10
11
12
13
14
15
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
Terminal function 16
Multi-step speed
terminal 1
Terminal function 17
Multi-step speed
terminal 2
Terminal function 18
Multi-step speed
terminal 3
Terminal function 19
Multi-step speed
terminal 4
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Multi-step speed
0
1
2
3
4
5
6
7
Frequency-hold
Valid
Invalid
Related parameter list:
Function
code
Name
Description
Default
value
P05.01
–
P05.06
Digital input function
selection
16: Multi-step speed terminal 1
17: Multi-step speed terminal 2
18: Multi-step speed terminal 3
19: Multi-step speed terminal 4
20: Multi-step speed pause
P10.02
Multi-step speed 0
-300.0
–300.0%
0.0%
P10.03
Running time of 0
th
step
0.0
–6553.5s (min)
0.0s
P10.04
Multi-step speed 1
-300.0
–300.0%
0.0%
P10.05
Running time of 1
st
step
0.0
–6553.5s (min)
0.0s
P10.06
Multi-step speed 2
-300.0
–300.0%
0.0%
P10.07
Running time of 2
nd
step 0.0
–6553.5s (min)
0.0s
P10.08
Multi-step speed 3
-300.0
–300.0%
0.0%
P10.09
Running time of 3
rd
step
0.0
–6553.5s (min)
0.0s
P10.10
Multi-step speed 4
-300.0
–300.0%
0.0%
P10.11
Running time of 4
th
step
0.0
–6553.5s (min)
0.0s