Goodrive350 IP55 High-ingress Protection Series VFD
Product Overview
-10-
Function description
Specification
Motor switchover
Supports two groups of motor parameters to control motor
switchover.
Peripheral
interface
Terminal analog input
resolution
No more than 20mV
Terminal digital input
resolution
No more than 2ms
Analog input
2 inputs, AI1: 0
–10V/0–20mA; AI2: -10–10V
Analog output
1 output, AO1: 0
–10V /0–20mA
Digital input
Four regular inputs; max. frequency: 1kHz; internal
impedance: 3.3k
Ω
Two high-speed inputs; max. frequency: 50kHz; supports
quadrature encoder input; with speed measurement
function
Digital output
One high-speed pulse output; max. frequency: 50kHz
One Y terminal open collector output
Relay output
Two programmable relay outputs
RO1A NO, RO1B NC, RO1C common port
RO2A NO, RO2B NC, RO2C common port
Contact capacity: 3A/AC250V, 1A/DC30V
Extension interface
Three extension interfaces: SLOT1, SLOT2, SLOT3
Expandable PG card, programmable expansion card,
communication card, I/O card, etc
Others
Installation mode
Support wall-mounting and flange-mounting
Operation ambient
temperature
-10
–50°C
Ingress protection
rating
IP55
Cooling mode
Forced-air cooling
Brake unit
Built-in brake units are included in the standard
configuration of 37kW or lower VFDs. VFDs of 45
–110kW
support optional built-in brake units. A VFD model with
built-in brake unit ends with "-B", for example,
GD350-045G/055P-45-AS-B.
EMC filter
Conducted emissions of all 380V models meet the
requirements of C3 in the IEC/EN 61800-3 standard.
External filter is optional: Conducted emission can meet the
requirements of C2 in the IEC/EN 61800-3 standard.
Note:
It is required to observe the EMC compliance
required by the appendix of the manual. The motor and
motor cables shall be selected based on technical
requirements specified in the appendix of the manual.
STO certification level Meet the SIL2 level