47
Code
Item
Range
Unit
d23
Flow reference
voltage
[0,10.00]
V
d24
Pressure
reference
voltage
[0,10.00]
V
d25
Pressure
feedback
voltage
[0,10.00]
V
d26
Output voltage [-1000,1000]
V
d27
Digital
input/output
ALM_RST
I1
I7
O2
I3
S_ON
I8
O1
I4
I6
I5
I2
S_RDY
ALM
When the input signal is valid, the LED turns off. For
example, when I1 has signal, the LED turns off; when I1
has no signal, the LED turns on (when S_ON input port
indicator is on, it is high level). When the output signal is
invalid, the LED turns on; when the output signal is valid,
the LED turns off.
-
d28
Motor
configuration
table version
-
-
d29
Motor power
[-327.67,327.67]
kW
d30
Energy
consumption for
this run
[0,999.9]
kW.h
d31
Five low bits of
accumulative
power
consumption
[0,999.9]
kW.h
d32
Five high bits of
accumulative
power
consumption
[0,9999]
1000
kW.h
d33
Motor power
factor
[0,1.00]
-
5.2.5 Setup mode
If you press the
MODE
key to select the setup mode, the LED value places display "F--xxx", in
which "xxx" indicates a parameter ID. You can press the
or
key to select a