background image

 

 

14 

 

2.6    Internal HDD Installation 

 

The IW-RS104-07 offers 3 x 2.5" internal SSD drive bays, and one of the 2.5" internal SSD 
drive bays can be replaced with an ODD. These drive bays can be mixed by customers into 
several combinations. 

 

 

 

 

 

For a quick installation video, please visit 

IW-RS104-07 Internal HDD Installation

.   

 

2.7  Connecting Cables   

InWin backplanes (without Expander) are high-performance and cost-effective solutions 
for  supporting  Intel®  Xeon  Scalable  family  by  adding  NVMe  support.  The  passive 
backplanes  support  state-of-the-art  SAS3  12Gbps  HDD/SSD  and  are  also  backward 
compatible with SAS 6Gbps, SATA 6Gps and SATA 3Gps HDD/SSD. Some of the backplanes 
support NVMe SSDs through either Oculink x 4 or Slimline x 4 connectors. 

 

2.7.1

 

Connecting Backplane Through SAS Connectors 

The  InWin  IW-RS104-07  needs  the  SAS  cable  to  connect  to  the  backplane  and  your 
motherboard  or  RAID  controller.  InWin  provides  verified  SAS  cables  for  installation, 
please contact InWin sales reps to get more information. 

 

2.7.2

 

Connecting LED Cable, Front Control Panel and Front USB I/O Ports 

As 1.3.1 describes, the InWin IW-RS104-07 has a built-in front control panel and USB 
access  ports.  To  activate  these  functions,  you  should  connect  the  pins  to  the 
motherboard.  Please  refer  to  the  motherboard’s  user  guide  to  make  sure  the  pin 
functions and their correct locations before attempting to connect them. 

 

 

 

 

 

 

 

 

 

 

 
 
 

USB 3.0 

LED Connector 

Summary of Contents for IW-RS104-07

Page 1: ...IW IW IW IW RS104 RS104 RS104 RS104 07 07 07 07 User Manual User Manual User Manual User Manual ...

Page 2: ...d Expansion Card Installation 11 2 2 HDD Tray Installation 11 2 3 Backplane Connection 11 2 4 Fan Installation 11 2 5 Power Supply Installation 11 2 5 1 Power Supply Cable Information 12 2 6 Internal HDD Installation 14 2 7 Connecting Cables 14 2 7 1 Connecting Backplane Through SAS Connectors 14 2 7 2 Connecting LED Cable Front Control Panel and Front USB I O Ports 14 2 8 Installing the Slide Rai...

Page 3: ...3 Backplane Introduction 18 4 Compatibility Lists 19 5 Q A 20 6 Technical Support 21 ...

Page 4: ... from sources of heat including direct sunlight and radiators It should be kept away from sources of vibration or physical shock The space should be accommodated with a properly grounded wall outlet and with sufficient space to access the power supply cords The operating environment temperature should be around 0 C to 40 C 32 F to 104 F Heed Safety Instructions Before working with InWin IPC storag...

Page 5: ...er carefully and plug the jumper to cover the jumper pins on the backplane Once you need to remove the jumper grip the jumper and carefully pull without squeezing CAUTION To avoid damage and maintain your safety please read the following terms listed below 1 Do not populate hard drives and turn on the power until the system has stabilized Make sure hard drives and other components are properly con...

Page 6: ...D NVMe SAS SATA SFF 8639 x 4 Backplane 3 Host Mini SAS HD SFF 8643 x 1 HDD SAS SATA x 4 Cooling Fan 40 x 56mm PWM easy swap fans x 6 21500RPM modular design with anti vibration Expansion Slot Full height PCIe slot x 1 via riser card Material Material SGCC Thickness 1 0mm Rail Kit Supports 28 tool less ball bearing slide rails Product Dimensions D x W x H Chassis Only 676 5 x 438 x 43 4mm 26 6 x 17...

Page 7: ...4 Product Dimensions ...

Page 8: ...4 HDD Interface NVMe SAS SATA SFF 8639 x 4 Backplane 2 Oculink Backplane Dimensions W x H 416 6mm x 33mm Backplane Type Passive Host Interface Mini SAS HD SFF 8643 x 1 Oculink SFF 8611 x 4 HDD Interface NVMe SAS SATA SFF 8639 x 4 Backplane 3 SAS SATA Backplane Dimensions W x H 416 6mm x 33mm Backplane Type Passive Host Interface Mini SAS HD SFF 8643 x 1 HDD Interface SAS SATA x 4 ...

Page 9: ...6 1 Product Introduction 1 1 Box Contents When you open the IW RS104 07 box the contents should include following ...

Page 10: ...to 2 pin Adapter x 1 9 2 5 SSD screws x 24 4 Cable Ties and Mounts x 5 10 Backplane Jumper x 1 5 Motherboard Screws x 11 11 Single Power Supply Accessories a Countersunk Flat Head Screws x 2 b Oval Head Screws x 4 c Mounting Bracket x 1 6 Motherboard Stand off Sockets x 11 12 Redundant Power Supply Accessories a Screws x 6 b Mounting Brackets x 2 ...

Page 11: ...8 1 3 General Information When you open the chassis it should reflect the diagram s image ...

Page 12: ...2 Power ON OFF Button with LED Blue Solid on System is powered on Off System is off 3 NMI Button No LED function Press the button to activate user defined function 4 System Reset Button No LED function Press the button to activate system reset 5 USB3 0 Connector No LED function USB devices connections 6 LAN LED LAN1 LAN4 Amber Blinking Link between system and network Off No data transmission or re...

Page 13: ...rence InWin compatibility list to select the compatible models 2 System I O Depends on M B Specifications InWin offers a customized service for 1U I O shield For more information please contact InWin s sales reps 3 Full Height PCIe Slot x 1 The slot supports standard high profile cards The bracket should be removed before using ...

Page 14: ...tion video please visit 07 Series HDD Tray Installation 2 3 Backplane Connection The IW RS104 07 supports three high end backplanes including Slimline Oculink and Mini SAS HD For a quick installation video please visit 07 Series SAS SATA Backplane Connection and 07 Series Oculink and Slimline Backplane Connection 2 4 Fan Installation The IW RS104 07 s built in fan modules feature a tool less desig...

Page 15: ...12 2 5 1 Power Supply Cable Information 650W Single PSU Cable Information Length Unit mm ...

Page 16: ...13 750W Redundant PSU Cable Information Length Unit mm ...

Page 17: ... SATA 6Gps and SATA 3Gps HDD SSD Some of the backplanes support NVMe SSDs through either Oculink x 4 or Slimline x 4 connectors 2 7 1 Connecting Backplane Through SAS Connectors The InWin IW RS104 07 needs the SAS cable to connect to the backplane and your motherboard or RAID controller InWin provides verified SAS cables for installation please contact InWin sales reps to get more information 2 7 ...

Page 18: ...nstructions to mount the rail onto your cabinet or chassis rack 2 8 2 Installing the Slide Rail Step 1 Release the inner rail from the slide No Connector Name Color Front I O Indication P2 NMI Switch Black Brown NMI Button P3 Reset Switch Red Orange Power Reset Button with LED P4 LAN LED 4 Yellow Green LAN LED P5 LAN LED 3 Blue Purple LAN LED P6 LAN LED 2 Gray White LAN LED P7 LAN LED 1 Black Brow...

Page 19: ...the arrows show Step 3 Install the outer rails and the brackets onto the rack 2 8 3 Mounting the chassis onto the cabinet Step 1 Make sure the ball bearing retainer is at the forefront Step 2 Insert the inner rail to the outer rail which has already locked up on the cabinet ...

Page 20: ...17 Step 3 Mount the inner rail onto the chassis by the direction which the arrows show on the image Step 4 Tighten the thumb screws to secure the chassis ...

Page 21: ...der Please reference the backplane user guide to complete the installation The download link is at the download section of each product Please visit the InWin website ipc in win com SAS3 Backplane Top Side Bottom Side Oculink Backplane Top Side Bottom Side ...

Page 22: ...ut 3 GND FAN1 FAN12 Connect to fan modules The backplane supports up to 12 fan modules 4 Compatibility Lists To reach the best performance and avoid system failure InWin strongly recommends customers to choose the components from InWin s compatibility list All the components are tested in InWin s lab and assured the components are compatible with InWin s chassis You can download the latest updated...

Page 23: ...he best performance we recommend following the motherboard or RAID controller vendors instructions d Does the chassis support SSDs or flash NVMe drives A SAS SATA and NVMe SSD connections can be attached to the InWin IW RS104 07 We recommend customers refer to InWin s compatibility list to confirm if the SSDs are listed or please contact InWin s sales reps for better reference e If I don t need th...

Page 24: ...t a solid hardware RAID system it is required However whether you should use the RAID controller card or not depends on your purpose and budget We recommend discussing with InWin s channel partners for their suggestions i Where can I buy the SAS cable A The 12Gb SAS to 4 SATA or 12Gb SAS to 6Gb SAS are standard cables that you can easily buy from many vendors You can buy the verified cable from In...

Reviews: