19 

 

5

 

Q & A     

a.

 

What is the function of the backplane?       

A: The backplane is the bridge which connects the hard drives and exports the signal to the 
motherboard. Also, the backplane provides the LED signals indicating the status of the hard 
drives, and alarming when the system temperature is abnormal. 

 

b.

 

Does the backplane support 6Gb SAS? 

A: The InWin IW-RS110-07 is accommodated with 12Gb SAS backplane by default. The 12Gb 
SAS  connector  interface  (SFF-8643)  is  not  compatible  with  6Gb  SAS.  InWin  provides 
OEM/ODM services, so customers may contact InWin sales reps for customization. 

 

c.

 

Does the chassis support 3.5

"

, 2.5

"

, SAS and SATA drives? Can I mix the different types of 

drives in an enclosure? 

A: The InWin IW-RS110-07 supports 2.5" (15mm) form factor’s SAS/SATA disks. Yet, to reach 
the  best  performance,  we  recommend  following  the  motherboard  or  RAID  controller 
vendors’ instructions. 

 

d.

 

Does the chassis support SSDs or flash NVMe drives? 

A: SAS/SATA and NVMe SSD connections can be attached to the InWin IW-RS110-07. We 
recommend customers refer to InWin’s compatibility list to confirm if the SSDs are listed, or 
please contact InWin’s sales reps for better reference. 
 

e.

 

If I don’t need the front cover, can I have the standard handle?

 

A: The InWin IW-RS110-07 supports both the standard handle and the bezel handle. If you 
would like your chassis with a standard metal handle, please contact your local sales reps to 
purchase the bezel package. 

 

f.

 

Can it support small form factor motherboards such as M-ATX and Mini-ITX? 

A: The InWin IW-RS110-07 supports motherboards that range from Mini-ITX to EEB. Unless 
you would like to mount a customized motherboard, which will not meet Intel’s standard, 
you will need to contact InWin’s partners or sales reps for customization services.   

 

g.

 

Do I need a RAID controller card to connect the backplane? 

A: If you would like to construct a solid hardware  RAID system, it is required. However, 
whether  you  should  use  the  RAID  controller  card  or  not  depends  on  your  purpose  and 
budget. We recommend discussing with InWin’s channel partners for their suggestions. 
 

Summary of Contents for IW-RS110-07

Page 1: ...IW IW IW IW RS110 RS110 RS110 RS110 07 07 07 07 User Manual User Manual User Manual User Manual ...

Page 2: ...0 2 1 Motherboard Expansion Card Installation 10 2 2 HDD Tray Installation 10 2 3 Fan Installation 10 2 4 Power Supply Installation 10 2 4 1 Power Supply Cable Information 10 2 5 Connecting Cables 13 2 5 1 Connecting Backplane Through SAS Connectors 13 2 5 2 Connecting LED Cable Front Control Panel and Front USB I O Ports 13 2 6 Installing the Slide Rail 14 2 6 1 Identifying the Slide Rail 14 2 6 ...

Page 3: ...4 Compatibility Lists 18 5 Q A 19 6 Technical Support 20 ...

Page 4: ... from sources of heat including direct sunlight and radiators It should be kept away from sources of vibration or physical shock The space should be accommodated with a properly grounded wall outlet and with sufficient space to access the power supply cords The operating environment temperature should be around 0 C to 40 C 32 F to 104 F Heed Safety Instructions Before working with InWin IPC storag...

Page 5: ...er carefully and plug the jumper to cover the jumper pins on the backplane Once you need to remove the jumper grip the jumper and carefully pull without squeezing CAUTION To avoid damage and maintain your safety please read the following terms listed below 1 Do not populate hard drives and turn on the power until the system has stabilized Make sure hard drives and other components are properly con...

Page 6: ...r SAS protocol SSD 8639 x 10 for NVMe SAS SATA device Cooling Fan 40 x 56mm PWM easy swap fans x 6 21500RPM modular design with anti vibration Expansion Slot Full height PCIe slot x 1 via riser card Material Material SGCC Thickness 1 0mm Rail Kit Supports 28 tool less ball bearing slide rails Product Dimensions D x W x H Chassis Only 676 5 x 438 x 43 4mm 26 6 x 17 2 x 1 7 Packaging Dimensions D x ...

Page 7: ...ace Slimline internal SFF 8654 x 10 for PCIe protocol 8643 x 3 for SAS protocol HDD Interface 8639 x 10 for NVMe SAS SATA device Backplane 2 Oculink Backplane Dimensions W x H 400mm x 37 3mm Backplane Type Passive Host Interface Oculink internal SFF 8611 x 10 for PCIe protocol 8643 x 3 for SAS protocol HDD Interface 8639 x 10 for NVMe SAS SATA device ...

Page 8: ...5 1 Product Introduction 1 1 Box Contents When you open the IW RS110 07 box the contents should include following ...

Page 9: ...Standoffs x 2 3 Power LED 3 pin to 2 pin Adapter x 1 8 Backplane Jumper x 1 4 Cable Ties and Mounts x 5 9 Redundant Power Supply Accessories a Screws x 6 b Mounting Brackets x 2 5 Motherboard Screws x 11 10 Single Power Supply Accessories a Countersunk Flat Head Screws x 2 b Oval Head Screws x 4 c Mounting Bracket x 1 ...

Page 10: ...7 1 3 General Information When you open the chassis it should reflect the diagram s image ...

Page 11: ... the button to activate user defined function 3 Power On Off Button with LED Green Solid on System is powered on N A Off System is off 4 Chassis ID Button with LED Blue Solid on Press the button to activate system identification 5 Hard Disk LED Amber Blinking System HDD accessing 6 System Fail LED Amber Solid on System Status Green Solid on System Status 7 LAN LED LAN1 LAN2 Green Blink Link betwee...

Page 12: ...ence InWin s compatibility list to select the compatible models 2 System I O Depends on M B Specifications InWin offers a customized service for 1U I O shield For more information please contact InWin s sales reps 3 Full Height PCIe Slot x 1 The slot supports standard high profile cards The bracket should be removed before using ...

Page 13: ...ol less trays Users no longer need to use screws to mount disks and can swap drives faster For a quick installation video please visit 07 Series HDD Tray Installation 2 3 Fan Installation The IW RS110 07 s built in fan modules feature a tool less design which makes it easy to maintain For a quick installation video please visit 07 Series Fan Installation 2 4 Power Supply Installation The IW RS110 ...

Page 14: ...11 650W Single PSU Cable Information Length Unit mm ...

Page 15: ...12 750W Redundant PSU Cable Information Length Unit mm ...

Page 16: ...gh SAS Connectors The InWin IW RS110 07 needs the SAS cable to connect to the backplane and your motherboard or RAID controller InWin provides verified SAS cables for installation please contact InWin local partners and sales to get more information 2 5 2 Connecting LED Cable Front Control Panel and Front USB I O Ports As 1 2 1 describes the InWin IW RS110 07 has a built in front control panel and...

Page 17: ... rail package and follow the instructions to mount the rail onto your cabinet or chassis rack 2 6 2 Installing the Slide Rail Step 1 Release the inner rail from the slide No Connector Name Color Front I O Indication CN2 ID LED Red Black Chassis ID Button with LED CN3 System LED Yellow Green System Fail LED CN4 ID Switch Green Black Chassis ID Button with LED CN5 Power LED Red Black Power ON OFF Bu...

Page 18: ...the arrows show Step 3 Install the outer rails and the brackets onto the rack 2 6 3 Mounting the chassis onto the cabinet Step 1 Make sure the ball bearing retainer is at the forefront Step 2 Insert the inner rail to the outer rail which has already locked up on the cabinet ...

Page 19: ...16 Step 3 Mount the inner rail onto the chassis by the direction which the arrows show on the image Step 4 Tighten the thumb screws to secure the chassis ...

Page 20: ...r Please reference the backplane user guide to complete the installation The download link is at the download section of each product Please visit the InWin website ipc in win com Oculink Backplane Top Side Bottom Side Slimline Backplane Top Side Bottom Side ...

Page 21: ...2 Connect to fan modules The backplane supports up to 12 fan modules NVME1 NVME10 NVMe interfaces connect to NVMe HBA 4 Compatibility Lists To reach the best performance and avoid system failure InWin strongly recommends customers to choose the components from InWin s compatibility list All the components are tested in InWin s lab and assured the components are compatible with InWin s chassis You ...

Page 22: ...and NVMe SSD connections can be attached to the InWin IW RS110 07 We recommend customers refer to InWin s compatibility list to confirm if the SSDs are listed or please contact InWin s sales reps for better reference e If I don t need the front cover can I have the standard handle A The InWin IW RS110 07 supports both the standard handle and the bezel handle If you would like your chassis with a s...

Page 23: ...that you can easily buy from many vendors You can buy the verified cable from InWin to eliminate compatibility issues 6 Technical Support If you need help with installation or troubleshooting you can contact your local InWin sales reps or send an e mail to InWin s local contacts for technical assistance ...

Reviews: