3.1.3 Main components
LBK System Series is composed of a control unit and up to six sensors. The Inxpect Safety application allows
system operation configuration and checks.
3.1.4 Control unit - sensor communication
The sensors communicate with the control unit via CAN bus using diagnostic mechanisms in compliance with
standard EN 50325-5 to guarantee SIL 2 and PL d.
For correct functioning, each sensor must be assigned an identification (Node ID).
Sensors on the same bus must have different Node IDs. By default, the sensor does not have a pre-assigned
Node ID.
3.1.5 Control unit - machinery communication
The control units communicate with the machinery via I/O ("Inputs" on page 20 and "Outputs" on page 21).
The ISC-B01 control unit is provided with a safety communication on a Fieldbus interface. The Fieldbus interface
allows the ISC-B01 control unit to communicate in real-time with the PLC of the machinery in order to do the
following:
l
send information about the system to the PLC (e.g. the position of the detected target)
l
receive information from the PLC (e.g. to change the configuration dynamically)
See "Fieldbus communication" on page 26.
The ISC-B01 and ISC-02 are provided with an Ethernet port that allows an unsafe communication on a Modbus
interface. See "Modbus communication" on page 27.
3.1.6 Applications
LBK System Series integrates with the machinery control system: when performing safety functions or detecting
failures, LBK System Series deactivates the safety outputs and keeps them deactivated, so the control system
can put the area into a safe condition and/or prevent restarting of the machinery.
In the absence of other control systems, LBK System Series can be connected to the devices that control the
power supply or machinery start-up.
LBK System Series does not perform normal machinery control functions.
For connection examples, see "Electrical connections" on page 91.
3. Get to know LBK System Series
LBK System Series | Instruction manual v1.2 SET 2021| SAF-UM-LBKBus-en-v1.2 | © 2020-2021 Inxpect SpA