5. Sensor position
5.6.2 Recommendations for covering the sensor
Below are some recommendations for creating and installing a sensor cover:
l
height from sensor: 15 cm (6 in)
l
width: minimum 30 cm (11.8 in), maximum 40 cm (15.7 in)
l
protrusion from the sensor: minimum 15 cm (6 in), maximum 20 cm (7.9 in)
l
water outflow: at the sides or behind but not in front of the sensor (the cover should be arched and/or tilted
backwards)
5.6.3 Recommendations for positioning the sensor
Below are some recommendations for defining the sensor position:
l
height above the ground: minimum 10 cm (3.9 in)
l
suggested inclination: 10° for 50° field of view and 20° for 110° field of view
Before installing a sensor facing downwards, make sure there are neither liquids nor reflective materials on the
floor.
Note
: during the restart prevention function or if the sensor has a 110° field of view, undesired alarms may occur
due to the higher sensitivity of the system.
5.6.4 Position not exposed to precipitation
If the installation position of the sensor is not exposed to precipitation, no special precautions are required.