68
LBK System Series | Instruction manual v1.2 SET 2021 | SAF-UM-LBKBus-en-v1.2 | © 2020-2021 Inxpect SpA
6. Installation and use procedures
6.2.9 Chain examples
Chain with control unit at the end of the chain and a sensor with bus terminator
Chain with control unit inside the chain and two sensors with bus terminator
6.2.10 Save and print the configuration
1. In the application, click
APPLY CHANGES
: the sensors will save the inclination set and the surrounding
environment. The application will transfer the configuration to the control unit, and once transfer is complete
it will generate a configuration report.
2. Click to save and print the report.
3. Ask the authorized person for a signature.
6.2.11 Set the control unit Ethernet parameters
1. Ensure the control unit is turned on.
2. Press the Network parameter reset button and hold it down during steps 3 and 4.
3. Wait for five seconds.
4. Wait until all the six LEDs on the control unit turns steady green: the Ethernet parameters are set to their
default values (see "Ethernet connection (if available)" on page 87).
5. Configure the control unit again.
6.3 Validate the safety functions
6.3.1 Validation
Once the system has been installed and configured, check that the safety functions are activated/deactivated as
expected and that the dangerous area is monitored by the system.
WARNING! The Inxpect Safety application facilitates installation and configuration of the system,
but the validation process described below is still required.