2.1.8 WARNINGS FOR THE RESTART PREVENTION FUNCTION
l
The restart prevention function is not guaranteed in blind spots. If required by the risk assessment, implement
adequate safety measures in those areas.
l
Machinery restarting must be enabled only in safe conditions. The button for the restart signal must be
installed:
o
outside of the dangerous area
o
not accessible from the dangerous area
o
in a point where the dangerous area is fully visible
2.1.9 RESPONSIBILITY
The machinery manufacturer and system installer are responsible for the operations listed below:
l
Providing adequate integration of the safety output signals of the system.
l
Checking the monitored area of the system and validating it based on the needs of the application and risk
assessment. Following the instructions provided in this manual.
2.1.10 LIMITS
l
The system cannot detect the presence of people who are immobile and not breathing or objects within the
dangerous area.
l
The system does not offer protection from pieces ejected from the machinery, from radiation, and objects
falling from above.
l
The machinery command must be electronically controlled.
2.1.11 DISPOSAL
In safety-related applications, comply with the mission time reported in "General specifications" on page 79.
For decommissioning follow the instructions reported in "Disposal" on page 100.