92
SBV System Series | Instruction manual v1.2 DEC 2021 | SAF-UM-SBVBus-en-v1.2 | © 2021 Inxpect SpA
8. Technical references
Parameter
Min
Max
Default value
Position (for each sensor)
X: 0 mm
Y: 0 mm
X: 65000 mm
Y: 65000 mm
Default position of
sensor #1:
X: 1000 mm
Y: 1000 mm
Rotation (for each sensor)
0°
359°
0°
Inclination (for each sensor)
-90°
90°
0°
Sensor installation height (for each sensor) 0 mm
10000 mm
0 mm
Detection Distance 1(for each sensor)
0 mm
5000 mm
1000 mm
Detection Distance 2, 3 and 4 (for each
sensor)
0 mm
5000 mm
Note
: the sum of all
the detection
distances (for each
sensor) must not
exceed 5000 mm.
0 mm
Angular coverage
10°
100°
100°
Safety working mode (for each detection
field of each sensor)
Both (default), Always access detection,
Always restart prevention
Both (default)
Static object detection (for each detection
field of each sensor)
Enabled, Disabled
Disabled
Restart timeout (for each detection field of
each sensor)
100 ms
60000 ms
4000 ms
T
OFF
100 ms
60000 ms
100 ms
Settings > Sensors
Detection field dependency
Enabled, Disabled
Enabled
Anti-masking
Disabled, Low, Medium, High
High
Anti-masking distance
0 mm
1000 mm
1000 mm
Anti-rotation around axes
Disabled, Enabled
Enabled
Anti-rotation around axes - Enable specific
axes - Tilt
Disabled, Enabled
Enabled
Anti-rotation around axes - Enable specific
axes -Roll
Disabled, Enabled
Enabled
Anti-rotation around axes - Enable specific
axes - Pan
Disabled, Enabled
Enabled
Settings > Digital Input-Output
Digital input (for each input)
Stop signal, Restart signal, Muting group
“N”, Activate dynamic configuration,
Fieldbus controlled
Not configured
Digital output (for each output)
System diagnostic signal, Muting enable
feedback signal, Fieldbus controlled,
Restart Feedback signal, Detection signal
"N"
Not configured
OSSD Pulse width
Short (300 μs), Long (2 ms)
Short (300 μs)
Settings > Muting
Group for muting (for each sensor)
None, Group 1, Group 2, both
Group 1
Pulse width (for each Input TYPE)
0 μs (= Period and
Phase shift disabled)
200 μs
2000 μs
0 μs
Period (for each Input TYPE)
200 ms
2000 ms
200 ms
Phase shift (for each Input TYPE)
0.4 ms
1000 ms
0.4 ms
Settings > Restart parameters
Detection field 1, 2, 3, 4
Automatic, Manual, Safe manual
Automatic
Summary of Contents for SBV System Series
Page 101: ......