Federal Communications Commission (FCC) Statement

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant 
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 
interference in a residential setting. This product generates, uses, and can radiate radio frequency energy 
and, if not installed and used as directed, it may cause harmful interference to radio communications.  
Although this product complies with the limits for a Class A digital device, there is no guarantee that 
interference will not occur in a particular installation.   

Summary of Contents for GCS634U

Page 1: ...1 GCS634UW6 Part No M1013 a Installation Installation Guide 4 Port USB KVM Switch User Manual 4 Port USB KVM Switch GCS634U PART NO Q1013 a www iogear com ...

Page 2: ...ered trademark of International Business Machines Inc Macintosh G3 G4 and iMac are registered trademarks of Apple Computer Inc IOGEAR makes no warranty of any kind with regards to the information presented in this document All information furnished here is for informational purposes only and is subject to change without notice IOGEAR assumes no responsibility for any inaccuracies or errors that ma...

Page 3: ...3 Table of Contents Package Contents 4 System requirement 5 Introduction 6 Installation 7 Operation 8 Limited Warranty 17 Federal Communications Commission FCC Statement 18 CE Compliance 19 Contact 20 ...

Page 4: ... This package contains 1 4 Port KVM Switch two cables built in 2 Detachable custom KVM cables 1 User Manual 1 Quick Start Guide 1 Warranty Registration Card If any items are damaged or missing please contact your dealer ...

Page 5: ...ng on any computer in the installation A USB Keyboard A USB Mouse Computers The following equipment must be installed on each computer that is to be connected to the system A VGA SVGA or Multisync card A USB type A port A multimedia sound card for audio sharing Speakers Only 2 channel powered speakers are supported ...

Page 6: ... USB Keyboard Port 3 USB Mouse Port 4 VGA Monitor Port 5 Stereo Speaker Port 6 USB Plug black 7 VGA Plug blue 8 Audio Plug light green 9 Custom KVM Plug dark green 10 Custom KVM Ports Introduction 10 2 5 1 4 3 6 7 8 9 ...

Page 7: ...mouse port 2 Plug your monitor into the VGA port on the side of the switch 3 Plug your powered speakers into the audio jack on the side of the switch 4 Plug the extra KVM cables into the green ports on the back of the switch using the custom green connectors You may skip both or only one of these cables if only using two or three computers 5 Plug the VGA USB and audio connections on each of the KV...

Page 8: ...ribed in the next section and press T Then all of the following commands will work by simply pressing the Control key in place of the Scroll Lock key Scroll Lock Scroll Lock Enter This will switch everything KVM and sound to the next port Scroll Lock Scroll Lock number Enter This will switch everything KVM and sound to the exact port number typed The number must be be tween 1 and 4 and you must us...

Page 9: ...e Auto Scan mode the KVM focus cycles from port to port at a 5 second interval Scroll Lock Scroll Lock a n Enter This will start the Auto Scan mode the KVM focus cycles from port to port at a n second interval To exit Auto Scan mode press Esc or Spacebar ...

Page 10: ...n place of Num Lock If you have done this correctly the Caps Lock and Scroll Lock lights on the keyboard should begin flashing This means you are in hotkey mode which will be shortened to just HKM below If you are having trouble entering hotkey mode press Esc and try again Please read the following pages to learn how to use advanced hot keys to change the keyboard into Mac mode or Sun mode in orde...

Page 11: ...11 Mac keyboard Clear Minus ...

Page 12: ...12 PC keyboard Num Lock Minus ...

Page 13: ...he operating system of the currently active port to Macintosh This will allow the KVM to emulate special keys that are normally only present on an Apple keyboard HKM F3 This will manually set the operating system of the currently active port to Sun This will allow the KVM to emulate special keys that are normally only present on a Sun keyboard On some Sun computers it is necessary to set up the KV...

Page 14: ...ings Open a word processor before using this command in order to see how the KVM is configured HKM F5 This will reset the USB ports on the switch and may clear up any keyboard or mouse problems HKM R Enter This will reset all KVM settings to their defaults ...

Page 15: ...Ctrl is used in conjunction with other keys The corresponding functions are shown in the table to the right NOTE When using Ctrl combinations press and release the Ctrl key then press and release the activation key PC Keyboard Mac Keyboard Shift Shift Ctrl Ctrl Win Ctrl 4 Alt L Alt Option Prt_Sc F13 Scroll Lock F14 Desktop Menu Enter Return Back Space Delete Ins Help Ctrl Win F15 Ctrl 1 Mult Ctrl ...

Page 16: ...d The corresponding functions are shown in the table to the right NOTE When using key combinations press and release the first key Ctrl or Alt then press and release the activation key PC Keyboard Sun Keyboard Ctrl T Stop Ctrl F2 Again Ctrl F3 Props Ctrl F4 Undo Ctrl F5 Front Ctrl F6 Copy Ctrl F7 Open Ctrl F8 Paste Ctrl F9 Find Ctrl F10 Cut Ctrl 1 Ctrl 2 Ctrl 3 Ctrl 4 Ctrl H Help Compose Meta ...

Page 17: ...rmation 2 Visit www iogear com support for live help and product support Warranty Information This product carries a 3 Year Limited Warranty For the terms and conditions of this warranty please go to http www iogear com support warranty Register online at http www iogear com register Important Product Information Product Model Serial Number ...

Page 18: ...o provide reasonable protection against harmful interference in a residential setting This product generates uses and can radiate radio frequency energy and if not installed and used as directed it may cause harmful interference to radio communications Although this product complies with the limits for a Class A digital device there is no guarantee that interference will not occur in a particular ...

Page 19: ...19 CE Compliance This device has been tested and found to comply with the following European Union directives Electromagnetic Capability 2004 108 EC Low Voltage 2006 95 EC and R TTED 1999 5 EC ...

Page 20: ...20 Contact IOGEAR Toll Free 866 9 IOGEAR USA Phone 949 453 8782 19641 Da Vinci Foothill Ranch CA92610 www iogear com support iogear com ...