26
Flare 12M CXP User's Manual
Address
Name / Description
Group
Access Length
(bytes)
Description
0x2000000C
Window Update Status
R
4
After the Set Window register
is written, if all settings are
valid this register will return
0. A value of 1-8 indicates
which window settings are
invalid
0x30001004
Min HR
R
4
Minimum horizontal
resolution (64 pixels)
0x3000100C
Min VR
R
4
Minimum vertical resolution
(8 lines)
0x3000101C
Min Frame Period
R
4
Minimum frame period, in µs
0x30001020
Min Exposure 1
R
4
Minimum exposure time 1, in
µs
0x30001024
Min Exposure 2
R
4
Minimum exposure time 2, in
µs
0x30001028
Min Exposure 3
R
4
Minimum exposure time 3, in
µs
0x30002004
Max HR
R
4
Maximum horizontal
resolution
0x3000200C
Max VR
R
4
Maximum vertical resolution
0x3000201C
Max Frame Period
R
4
Maximum fame period, in µs
0x30002020
Max Exposure 1
R
4
Maximum exposure time 1,
in µs
0x30002024
Max Exposure 2
R
4
Maximum exposure time 2,
in µs
0x30002028
Max Exposure 3
R
4
Maximum exposure time 3,
in µs
0X300020DC
Maximum Lens Aperture
R
4
Maximum lens aperture
value (represents smallest
aperture)
0x40000000
Pixel Format
R/W
4
0x01080001 – Mono8
0x01100003 – Mono10
0x40000004
Output Horizontal Resolution
R/W
4
Horizontal resolution
0x40000008
ROI-1 HR Start
R/W
4
Start column on sensor.
0x4000000C
ROI-1 Vertical Resolution
R/W
4
Number of lines in image.
0x40000010
ROI-1 VR Start
R/W
4
Start line on sensor.
IO Industries Inc.
www.ioindustries.com
Revision 2.0