27
Flare 12M CXP User's Manual
Address
Name / Description
Group
Access Length
(bytes)
Description
0x40000014
Exposure Mode
R/W
4
0 – Free-Run Programmable
Exposure
1 – External Trigger
Programmable Exposure
2 – External Trigger Level
Exposure
0x40000018
HDR Mode
R/W
4
0 – Normal exposure
1 – Interleaved HDR mode
•
Exposure Mode 0/1
– Exposure 1 used
for odd columns,
Exposure 2 used for
even columns
•
Exposure 2 – not
available
2 – Interleaved HDR mode
with image fuse
3 – Piecewise HDR mode
•
Exposure Mode 2 –
not available
0x4000001C
Frame Period
R/W
4
Frame period, in µs
0x40000020
Exposure 1
R/W
4
Exposure time 1, in µs
0x40000024
Exposure 2
R/W
4
Exposure time 2, in µs
0x40000028
Exposure 3
R/W
4
Exposure time 3, in µs
0x4000002C
Piecewise HDR Number of
Slopes
R/W
4
Range 2 - 3
0x40000030
Piecewise HDR Voltage 1
R/W
4
Range 0x41 - 0x7F
0x40000034
Piecewise HDR Voltage 2
R/W
4
Range 0x40 - 0x7F
0x40000038
Sensor Top Offset
R/W
4
Range 0x001-0xFFF
Factory calibrated, changing
this value not recommended
0x4000003C
Sensor Bottom Offset
R/W
4
Range 0x001-0xFFF
Factory calibrated, changing
this value not recommended
0x40000040
Analog Gain
R/W
4
0 – x1 gain (default)
1 – x2
2 – x3
0x40000044
Digital Gain
R/W
4
Range 1-16383
Gain applied = (value)/1024
0x40000048
Sensor ADC Gain
R/W
4
Range 0x80 to 0xFF
Factory calibrated, changing
this value not recommended
IO Industries Inc.
www.ioindustries.com
Revision 2.0