49
Flare 12M CXP User's Manual
Center
Diamond
Zone 1 0000
Zone 1 1800
Zone 2 3c3c
Zone 2 7e3c
Zone 3 3c3c
Zone 3 3c7e
Zone 4 0000
Zone 4 0018
Plus Sign
Vertical
Zone 1 1818
Zone 1 1818
Zone 2 ff18
Zone 2 1818
Zone 3 18ff
Zone 3 1818
Zone 4 1818
Zone 4 1818
Horizontal
Zone 1 0000
Zone 2 ff00
Zone 3 00ff
Zone 4 0000
Figure 13. Example zone settings
3.9 Look-Up Table
The Flare CXP cameras have a custom Look-Up Table (LUT) in the data path. Up to 4
custom user LUTs can be stored in non-volatile memory in the camera. Use the
Look-Up
Table
register to load one of the four LUTs from memory, by writing a value from 1 to 4. Write
a 0 to disable the LUT block.
The LUT tables in the camera are 12-bit. For the best image quality the data path of the Flare
12M180 cameras carry extra decimal bits per pixel after the fixed pattern noise correction
IO Industries Inc.
www.ioindustries.com