Ioline FlexJet E User Guide
Reset Calibration Values
Perform the steps below if calibration values have been altered:
1.
With the printer in
STOP
mode, use the arrow keys to move
the carriage to the center of the traverse.
2.
Turn power off on the printer.
3.
Copy the factory calibration values from the white sticker
inside the service station (
see
Figure 35
.
) If no sticker is present,
recalibrate the machine using the procedure available in this
User Guide
.
4.
Press and hold the
Unroll
key on the keypad then turn printer
power on.
5.
When the
OK
light turns red, release the key.
6.
Use the
Control Center
software to re-enter the calibration
values copied from the sticker OR perform the calibration using
the directions in this chapter.
7.
Turn power off then back on to ensure the new calibration val-
ues take affect. Perform test plots to verify proper calibration
and operation.
8.
If you have any difficulties, please contact Ioline
Customer
Service.