47
Chapter 3: Troubleshooting & Testing
Adjusting the cartridge
alignment value
To align the cartridges on a two-
head FlexJet, run the plot file
70x8.plt
for 72-in wide paper, or
40x8.plt
for 63-in wide paper.
Compare the plot to
Figures
29
&
30.
Adjust the alignment
values for the second cartridge,
as indicated, in the
Calibration
Alignment
window to bring the
two lines into alignment.
It is not necessary to adjust
cartridge #1.
Figure 27.
The
Cartridge Calibration
window in the
Control Center.
Figure 29.
Increase the alignment value
for cartridge #2 to improve line quality.
Figure 30.
Decrease the alignment value
for cartridge #2 to improve line quality.
Figure 28.
The Cartridge Alignment
dialog box.
Start with a frame gap of -30, and
all cartridges set to zero so you
can see a separation between the
heads. This will make it easier to
line the heads up with each other.
Note