6. Functions & Operation 

I: DC Start Function 

DC  Start  Function  enables  UPS  to  be  started  up  when  AC  utility  power  is  not  available  and  battery  is  fully 
charged. Just simply press the power switch to turn on the UPS. 
 

II:  Green Power Function 

These series are equipped with Green Power Function for saving power and protecting battery. The feature of 
deep discharge protection is adoped on battery mode. If no load is connected to the UPS, it will automatically 
shut down after 5 minutes for  energy saving while running on  battery  mode. The UPS will restart while AC 
recovery. 
 

III: AVR (Automatic Voltage Regulation) 

If the quality of the incoming mains is poor, the AVR boosts a low incoming voltage or reduces a high one. The 
load receives a voltage within the normal range. 
 

IV: Auto restart while AC recovery 

 

V: Audio Indicator  

 

Audible Alarm 

Situation 

Sounding every 10 seconds 

 

Battery Mode

 

Sounding every 1 second

 

Battery Low

 

Sounding every 0.5 seconds

 

Overload

 

continuous sounding 

Faulty

 

7. Software Installation on your PC 

Connected  by  USB  to  a  PC  or  notebook,  the  Software  enables  communication  between  the  UPS  and  the 

computer.  The  UPS  software  monitors  the  status  of  the  UPS,  shuts  down  the  system  before  the  UPS  is 

exhausted and can remotely observe the UPS via the Network (enabling users to manage their system more 

effectively). Upon AC failure or UPS battery low, UPS takes all necessary actions without intervention from the 

system administrator. In addition to automatic file saving and  system shut-down functions, it can also send 

warning messages via pager, e-mail etc. 

 

Use the bundled CD and follow the on-screen instructions to install the software WinPower. 

 

Enter the following serial No. to install software: 511C1-01220-0100-478DF2A 

 

After  the software is successfully installed, the communication with UPS  has  been established and a 

green icon will appear in the system tray.   

 

Double-click the icon to use the monitor software (as above).     

 

You can schedule UPS shutdown/start-up and monitor UPS status through PC. 

 

Detail instructions please refer to the e-manual in the software.  

 

Check 

http://www.ups-software-download.com/index.htm

  from  time  to  time  to  get  the 

latest  
            version of monitoring software.

 

Summary of Contents for 1200 Australia

Page 1: ...F 11 LINE INTERACTIVE UPS UPS USER MANUAL 650VA 1200VA 2200VA GENERAL PURPOSE UPS...

Page 2: ...ollowing environments o Any area with combustible gas corrosive substance or heavy dust o Any area with extraordinarily high or low temperature above 40 C or below 0 C and humidity of more than 90 o A...

Page 3: ...in a fire The battery may explode Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic Icon on the rating label stands for phase symbo...

Page 4: ...onger and more reliability 2 Description of Features Easy to use and install utilized microprocessor control to maximize the reliability and efficiency Equipped with built in boost and buck AVR functi...

Page 5: ...VR mode it will display as below And the mark will flicker every 1second When in battery mode it will display as below And the mark will flicker every 1second Note If I P V 40V input voltage will disp...

Page 6: ...e 13 2V 11 5V battery voltage 12 5V 13 2V battery voltage 13 5V Battery voltage 12 5V Battery voltage 13 5V 2B model battery definition Battery Level Battery bar Indication Battery mode Other mode Bat...

Page 7: ...anel 650 Australia 1200 Australia 2200 Australia 1 AC input 2 2 Australia outlet 3 RJ11 Modem phone line protection 1 AC input 2 4 Australia outlet 3 USB port 4 RJ45 LAN Modem phone line protection 5...

Page 8: ...contaminants Please place the UPS away from other units at least 20 cm to avoid interference Do NOT operate the UPS where the temperature exceeds 0 40 C and the humidity is over 0 90 RH II Connect to...

Page 9: ...Connect from OUT outlet to the computer with another phone line cable V Connect USB Cable To monitor the UPS status such as unattended UPS shutdown and start up by using bundled software please connec...

Page 10: ...allation on your PC Connected by USB to a PC or notebook the Software enables communication between the UPS and the computer The UPS software monitors the status of the UPS shuts down the system befor...

Page 11: ...up to 8 hours 2 Battery defect 2 Replace with the same type of battery 3 Power switch is not pressed 3 Press the power switch again Alarm buzzer beeps continuously when AC supply is normal Overload o...

Page 12: ...ischarge overcharge and overload protection ENVIRONMENT Humidity 0 90 RH 0 to 40 C non condensing Noise Level Less than 40dB 45dB Software Monitoring Software WinPower included BATTERY Type Number 12V...

Page 13: ......

Reviews: