4. Product Overview 

Front Panel 

   

 

 
                                                650 Australia 

 

                    1200 Australia & 2200 Australia 

1.  Display 

When LCD starts to work, it will display all information 

for 3 seconds. 

 

When in normal mode, it will display as below. 

 
 

When in AVR mode, it will display as below. And the 

mark 

 will flicker every 1second. 

 

When  in  battery  mode,  it  will  display  as  below.  And 

the mark 

 will flicker every 1second. 

 

 
 
 
 
 
Note: If I/P-V<40V

input voltage will display “000” 

 

When in off charging mode, it will display as below. 

 
 
 
 
 
 

Note: the output voltage always is displayed as “000” 
in off charging mode. 

When in fault mode, it will display as below. “FAULT” 
character and “0” character only. 

 

 
 
 

Summary of Contents for 1200 Australia

Page 1: ...F 11 LINE INTERACTIVE UPS UPS USER MANUAL 650VA 1200VA 2200VA GENERAL PURPOSE UPS...

Page 2: ...ollowing environments o Any area with combustible gas corrosive substance or heavy dust o Any area with extraordinarily high or low temperature above 40 C or below 0 C and humidity of more than 90 o A...

Page 3: ...in a fire The battery may explode Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic Icon on the rating label stands for phase symbo...

Page 4: ...onger and more reliability 2 Description of Features Easy to use and install utilized microprocessor control to maximize the reliability and efficiency Equipped with built in boost and buck AVR functi...

Page 5: ...VR mode it will display as below And the mark will flicker every 1second When in battery mode it will display as below And the mark will flicker every 1second Note If I P V 40V input voltage will disp...

Page 6: ...e 13 2V 11 5V battery voltage 12 5V 13 2V battery voltage 13 5V Battery voltage 12 5V Battery voltage 13 5V 2B model battery definition Battery Level Battery bar Indication Battery mode Other mode Bat...

Page 7: ...anel 650 Australia 1200 Australia 2200 Australia 1 AC input 2 2 Australia outlet 3 RJ11 Modem phone line protection 1 AC input 2 4 Australia outlet 3 USB port 4 RJ45 LAN Modem phone line protection 5...

Page 8: ...contaminants Please place the UPS away from other units at least 20 cm to avoid interference Do NOT operate the UPS where the temperature exceeds 0 40 C and the humidity is over 0 90 RH II Connect to...

Page 9: ...Connect from OUT outlet to the computer with another phone line cable V Connect USB Cable To monitor the UPS status such as unattended UPS shutdown and start up by using bundled software please connec...

Page 10: ...allation on your PC Connected by USB to a PC or notebook the Software enables communication between the UPS and the computer The UPS software monitors the status of the UPS shuts down the system befor...

Page 11: ...up to 8 hours 2 Battery defect 2 Replace with the same type of battery 3 Power switch is not pressed 3 Press the power switch again Alarm buzzer beeps continuously when AC supply is normal Overload o...

Page 12: ...ischarge overcharge and overload protection ENVIRONMENT Humidity 0 90 RH 0 to 40 C non condensing Noise Level Less than 40dB 45dB Software Monitoring Software WinPower included BATTERY Type Number 12V...

Page 13: ......