background image

OPERATION MANUAL

Dated: 02/10/2015

Document Name: 30-35ACi+&Deluxe_OM

Page 1 of 12

30ACi+, 30ACi Deluxe,  

35ACi+ and 35ACi Deluxe

Battery Backup System

Register your product at www.sumpro.com

30ACi+

1.  600 va Inverter, PN: TW20313

2.  Battery Box, PN: EP0----300

3.  WC33M, PN: M5235033MN

4.  Ion+ Switch/Alarm, PN: iNP20306

5.  Ion Pipe Mount Bracket, PN: iN-SPB-1

6.  Battery Leads, PN: TW20354

30ACi Deluxe

1.  600 va Inverter, PN: TW20313

2.  Battery Box, PN: EP0----300

3.  (2) WC33M, PN: M5235033MN

4.  Ion Genesis, PN: iNG2-10-1B

5.  Battery Leads, PN: TW20354

35ACi+

1.  800 va Inverter, PN: TW20315

2.  Battery Box, PN: EP0----300

3.  BA33M, PN: HP20180

4.  Ion+ Switch/Alarm, PN: iNP20306

5.  Ion Pipe Mount Bracket, PN: iN-SPB-1

6.  Battery Leads, PN: TW20354

35ACi Deluxe

1.  800 va Inverter, PN: TW20315

2.  Battery Box, PN: EP0----300

3.  (2) BA33M, PN: HP20180

4.  Ion Genesis, PN: iNG2-10-1B

5.  Battery Leads, PN: TW20354

3

3

1

1

4

4

6

6

2

2

5

5

3

3

4

4

1

1

5

5

2

2

35ACi+

35ACi Deluxe

30ACi+

30ACi Deluxe

Summary of Contents for 30ACi Deluxe

Page 1: ... TW20354 30ACi Deluxe 1 600 va Inverter PN TW20313 2 Battery Box PN EP0 300 3 2 WC33M PN M5235033MN 4 Ion Genesis PN iNG2 10 1B 5 Battery Leads PN TW20354 35ACi 1 800 va Inverter PN TW20315 2 Battery Box PN EP0 300 3 BA33M PN HP20180 4 Ion Switch Alarm PN iNP20306 5 Ion Pipe Mount Bracket PN iN SPB 1 6 Battery Leads PN TW20354 35ACi Deluxe 1 800 va Inverter PN TW20315 2 Battery Box PN EP0 300 3 2 ...

Page 2: ...park able electrical devices or open flame when working on this unit WARNING Do not install unit in locations classified as hazardous per N E C ANSI NFPA 70 1999 FAILURE TO HEED ABOVE CAUTIONS COULD RESULT IN INJURY OR DEATH WARNING These systems are designed to operate only one pump at a time the one s supplied with the unit Using anything other than the pump supplied with the system will cause d...

Page 3: ...c CAUTION The electrolyte is a dilute sulfuric acid that is harmful to the skin and eyes It is electrically conductive and corrosive The following procedures should be observed a If electrolyte contacts the skin wash it off immediately b If electrolyte contacts the eyes flush thoroughly and immediately with water Seek medical attention c Spilled electrolyte should be washed down with a suitable ac...

Page 4: ...ting on DC Power 1 Follow Steps 1 4 above 2 Push and hold the Power button on the front of the inverter for 3 5 seconds Tools Needed A pipe wrench insulated pliers insulated adjustable wrench and insulated screwdriver will be needed Installation Instructions Remove all packing and contents from the battery box enclosure an inverter battery box pig tail with Anderson connector inverter power cord a...

Page 5: ...ower is available the Power button is automatically on If the button is held in for 3 5 seconds while in AC mode the display will go blank and the inverter will be off The inverter can be turned back on by holding in the Power button again for 3 5 seconds or unplugging the inverter from the wall outlet for 10 seconds and plugging it back in Note The range of the switch is the distance between the ...

Page 6: ... with AC power 120 volt The Anderson connector on the inverter leads gets connected to the Anderson connector on the Pig Tail coming from the battery Front Panel DC MODE AC MODE Output Voltage Output Voltage Amount of Load Amount of Load Battery Display Battery Display Charge in Batteries Charge in Batteries Frequency Load Amps Input Voltage Load Amps Pump Outlet Main Circuit Breaker Quick Connect...

Page 7: ... Boost Voltage 13 7 0 2 V Overload 130 3 With Auto Reset Function 30ACi 30ACi Deluxe 35ACi 35ACi Deluxe Inverter Specifications Inverter Specifications Model Output HP Amp Voltage WC33 1 3 4 0 115 Pump Specifications Model Output HP Amp Voltage BA33 1 3 4 5 115 Pump Specifications Technical Specifications 30ACi 30ACi Deluxe Pump Performance Curve 35ACi 35ACi Deluxe Pump Performance Curve 30ACi 30A...

Page 8: ... pump or switch Troubleshooting 1 Fan keeps turning on in AC mode a This is a normal function of the unit Every hour the unit checks the batteries and its functions During this time the fan may run for 1 10 minutes to keep the internal electronics cool 2 Inverter Mode but No Power a Check display to see if a low battery condition is present Remove all loads unplug the AC power cord for 10 sec and ...

Page 9: ...gged vent hole in pump case Drill a 1 8 inch hole into PVC pipe e Inlet holes in pump base are clogged Remove pump and clean the openings f Vertical pumping distance is too high Reduce distance or change the discharge fittings of the pump 11 Pump Runs and Pumps Out Sump but Does Not Stop a Unplug the pump switch plug from the inverter b Plug the pump back into the switch plug and plug the switch p...

Page 10: ...otor stator may be defective 15 Pump Does Not Turn On a Test the pump without the Ion switch alarm i Plug the pump directly into a wall outlet without plugging it into the Ion switch alarm plug ii If pump still does not run the pump may be defective iii If the pump does run continue to the next step b Test the Ion switch alarm with the pump i Plug the pump into the Ion switch alarm and plug the Io...

Page 11: ...OPERATION MANUAL Dated 02 10 2015 Document Name 30 35ACi Deluxe_OM Page 11 of 12 30ACi 30ACi Deluxe 35ACi and 35ACi Deluxe Battery Backup System Register your product at www sumpro com Notes ...

Page 12: ...ropolitan to correct a defect in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unless and until Buyer notifies Metropolitan in writing of the defect and then only if such notification is made prior to the expiration of the period set forth above 3 Process of Claims and R...

Reviews: