CONTROL PANEL AND OPERATION

A) 

On/off switch

 

Press button A to turn the unit on and off.

B) 

Ioniser/night light

 

The ioniser is set to automatically start running once the unit is switched on. Press button B once to 

turn the night light on; press it a second time to turn the ioniser off, and; press it a third time to turn 

both the ioniser and the night light off. 

C) 

Auto

 

Press Button C to activate the automatic humidity function, then the ideal humidity of 55% is 

maintained. When the humidity level in the room is less than the auto humidity level (55%), the 

humidifier will continue to produce moisture automatically. Once the room humidity level is met, the 

humidifier will turn itself off.

D) 

Timer setting

 

Press Button D to determine the operating time. It can be regulated to operate between 1 and 12 

hours or continuously. 

E) 

Humidity setting 

 

Set the desired humidity in % by pressing Button E. We recommend a relative humidity of between 

40% and 60%. The appliance can be regulated from 40% to 75%. If the humidity exceeds the 

desired setting, the appliance will turn itself off. The appliance will not turn itself off if it has been 

set for continuous operation (“Co”). The desired value is shown while you are making the selection. 

After a few seconds, the display automatically switches to the current value.

F) 

Mist emission setting

 

Press Button F to adjust between low, medium and high mist emission. We recommend setting it to 

low mist emission for night use.

G) 

Water level display

 

The appliance will show on the display (G) with flash warning when the water tank needs to be 

refilled.

Attention: 

A humidity level below 20% can be unhealthy and uncomfortable. The optimal humidity 

level is between 40-60%. If condensation forms on your windows or walls or the humidity % on the 

display reads above 70%, turn the unit off.

CLEANING AND MAINTENANCE 

In winter, the lack of humidity can dry out your skin and cause nasal irritation, frequent colds, sore 

throats and other respiratory conditions. Humidifiers provide relative humidity to protect our health. 

To get the most benefit from the humidifier and avoid product failure, please follow all maintenance 

instructions carefully. These steps are essential to prevent microorganisms from growing in the water 

within the humidifier. 

A) 

Daily maintenance

1. 

Before cleaning, turn the power off and unplug the unit from its electrical outlet. 

2. 

Remove the water tank from the base of the unit.

3. 

Carry the water tank to a sink, then drain and rinse the water tank thoroughly to remove any 

sediment or dirt. Wipe clean and dry it with a clean soft cloth or paper towel.

4. 

Refill the water tank with cool tap water as instructed in the Pre-Operating Instructions.

B) 

Weekly maintenance

1. Repeat steps 1-3 above.
2. 

Pour one cup of white vinegar (about 200ml) into the base in the main body and leave for about 

15 minutes. Then, wipe off the scale (especially in the transducer) with the soft brush.

3. 

Wipe off the scale and white vinegar solution using a clean soft cloth.

C) 

Maintenance caution

1. 

Never submerge the main body in water.

2. Do not use any solvents or aggressive cleaning agents to clean the unit.
3. 

Clean the internal parts with a soft cloth.

4. 

Use only the brush provided to clean the transducer. This should be done once a week. 

5. 

Use only the soft bristle portion of the brush when cleaning.

6. 

Change the water in the water tank at least once a week to ensure that water is not left standing 

more than one week. 

D) 

Storing the humidifier

1. Clean the unit as described above and dry thoroughly.
2. 

Preferably, store the unit in its original box.

3. Avoid exposing the unit to high temperatures.

E) 

Replacement of the filter cartridge (Optional)

 

Replace the filter cartridge every 6 months as follows: 

1. 

Unplug the unit before removing the water tank. Do not touch the water in the main body during 

operation.

2. 

Turn the water tank upside down and unscrew the water tank cap. The filter cartridge is attached 

to the inside of the cap.

3. 

Remove the old filter cartridge and insert the new filter cartridge.

4. 

Screw the tank cap tightly onto the water tank and replace the water tank onto the main body.

 

Additional note: 

The main material of the filter cartridge is grain resin.