4.5.4 Firmware 

 
Please only use the file supply from Aviosys distributor or Aviosys .   
 
There are two sections  :  Bootloader  & Firmware 
 
The firmware update function only support in LAN connection .  
Before update , please DO 

READ 

THE HI-LITE MESSAGE BLOW :   

 
 

It takes about 1 minute to upload   upgrade flash and be patient please. Caution! A 
corrupted image will hang up the system. 

 
 

 

 
 
 
To update the 9820 MT , please follow the instruction below to prevent anything happens like 

update incomplete

 or 

 hardware disable

 which may be caused by  wrongdoing  of updating :   

 
1) Turn off all chat programs including ( Skype, FB. QQ, AIM, Yahoo messenger 

….etc.)  

2) Check to make sure that all devices are turned on

 

safely and powered  

3) While updating do not turn off the power  
4) Make sure that the cable is connected firmly 
5) Do not interrupt the update process, the update must be completely finished . 
6) Turn off, any Spyware or antivirus software which may conflict with the update. 
7) Update firmware in the Local Area Network (LAN) 
8) Support  update under  32bit  Web Browser ( 32 bit version only   )  like  IE, Google Chrome,  . 

Do not use browser  at 64 bit version   

9) Please change the  PORT as 80  
10) 

Reboot and Do the Hardware Reset 

( keep pressing RESET  button for 10secs ) after  

update successfully.  

11) 

Clear the Cookies from the temporary file of PC 

 to avoid get the old webpage .  

 
Please also update the notice in webpage before update :  

 

 
 

Summary of Contents for 9820 MT Series

Page 1: ...1 IP Power 9820 MT User Manual Version V1 00 Firmware Version 1 19_565 Date Released JAN 2020...

Page 2: ...ility for the possible damage from using power adapters not provided by us 4 Do not shake the IP Power 9820 MT in any fashion 5 Please contact the dealer If IP Power 9820 MT is not working properly Co...

Page 3: ...11 3 3 1 LAN connect by IP Search software IPEDIT 12 3 3 2 Internet Setup 15 3 3 3 Using IP Service 15 4 WEB INTERFACE 17 4 1 Top Column 18 4 1 1 Device name 18 4 1 3 Time 19 4 2 Power Control 20 4 2...

Page 4: ...4 4 5 System Setting 51 4 5 1 Management 51 4 5 2 System Information 54 4 5 3 System Log 54 4 5 4 Firmware 55 5 OTHER WAYS TO CONTROL 56 5 1 CGI HTTP Commands 56 5 2 Telnet Control 58 6 FAQ 59...

Page 5: ...port SSL SNMP user can use public email like Gmail Hotmail Yahoo mail to get the advice of outlet status change User can also control by e mail without doing port forwarding port mapping and search th...

Page 6: ...control without PC 8 SYSLOG Support Log function send to assign IP address 9 2 USB ports A USB1 for USB Temperature Humidity Sensor 8871 USB e Meter 8870 USB to RS232 data transfer need external board...

Page 7: ...ontrol multiple Aviosys IP devices in same AP CNT software Cross Network Technology allows user eliminate set up work on any Router without port forwarding No Need to do Port Forwarding simply Plug Pl...

Page 8: ...etwork Connection For 10 100 Mbps network There are 2 network RJ45 connect NET1 Green for network connection NET2 Gray for by pass as hub function only Please connect NET1 to the Router Hub IP Switch...

Page 9: ...ange is 20 70 4 158 IR This area is for receiving the signal from handheld IR remote controller DI Dry Contact Power Light Device power DC 12V Out Supply DC 12V 1A power LCD Display Show the IP addres...

Page 10: ...may not get the IP address of 9820MT The default setting for 9820 MT to get IP is DHCP mode get IP form Router If user do not use router and connect the 9820 MT to your PC directly or connect to HUB...

Page 11: ...or 9820 MT which means the system reboot successfully 3 Then Connect the Ethernet cable RJ45 to the 9820 MT to your PC 6 Execute the software IPEDIT exe to get the IP as 192 168 1 169 7 Please make su...

Page 12: ...ct by IP Search software IPEDIT IP Edit is a search tool designed to search configure or access the IP Power 9820 MT from a local networked computer IP Power 9820 MT Default Login Password Default IP...

Page 13: ...the other network connection functions 3 Anti Virus software Firewall Please turn off the antivirus software firewall temporary 4 Power If there is no power go to 9820 MT please check the fuse part T...

Page 14: ...he first 3 segments of user 9820 MT IP Address must match the first 3 segments of user gateway IP First 3 Segment of Gateway Address 192 168 1 X So user new IP Address for the 9820 MT should be 192 16...

Page 15: ...s Setup Port Mapping Port Forwarding in your router Please check your Router owner s manual Use our own software IP Power Center Please refer to the IP Power Center manual in software section of www a...

Page 16: ...ted for the device and press the Search button 4 Find user device and double click on the screen and a IE window will pop up connecting to user device User device must be Port Forwarded for the login...

Page 17: ...tup of the IP Power 9820 MT The IP Power 9820 MT Console consists of six main sections which will be explained in details below 1 Top Column Device name Column Display for smart phone 2 Information Ti...

Page 18: ...0 MT Notice Please do not use symbol like _ as the character of the device name After apply the change please click Refresh of the webpage to get the display update 4 1 2 Column Display For Smartphone...

Page 19: ...Minutes Seconds To setup the Time Please go to System Management NTP Settings please press Apply to save the new setting There are 3 time sync solution Time Manual setting Current time sync with Local...

Page 20: ...time please refresh the webpage or use the TELNET command date to confirm the device time 4 2 Power Control The IO Control Section allows you to directly automatically control the outlets of the 9820...

Page 21: ...2 Power Cycle Manually Control the relay delay some times to turn ON or OFF The relay cycle time can be set from 1 to 9999 seconds As ON Select OFF and press Power cycle then the outlet status is ON...

Page 22: ...outlet will be ON for 3 seconds and then turn OFF ON 3 sec OFF Original Outlet as OFF select final status as OFF fill 15 sec After press power cycle button the outlet will turn ON for 8 seconds andth...

Page 23: ...ore than one outlet by press the right side Apply button For safety concern each port of 9820 MT will turn ON or OFF one after one Apply Setup the ON OFF by the buttons status Invert Apply Change the...

Page 24: ...racter is max 12 characters and Please change the name in English only and do not use symbol like _ Note Please change the name in English only and do not use symbol like _ Example Change the outlet 1...

Page 25: ...off manually Select by port will disable the power control in webpage The disable is for the control in webpage only The control through HTTP command is still working For Example Select the control in...

Page 26: ...ct the power cycle control in webpage of power 1 power 2 for be disable Email Alerts Use can enable disable the e mail alarm here The e mail alarm section allows 9820 MT to notify user by following si...

Page 27: ...the current limit setting 9820MT will keep short 2 beep for several times to remind the over loading issue happened and then turn off that output after a long beeping Temperature Alarm Setting to enab...

Page 28: ...is essential to install our software Please check the software in the SDK section of package CD File name Shutdown_On_LAN NOTE The delay time setup in this section is for Shutdown ON LAN procedure Not...

Page 29: ...outlet 5 8 Or Loop Temperature Volt IP IP Current of outlet 1 4 Current of outlet 5 8 display in turns Adjust the back light on off the LCD panel Wake on Lan settings This is a application for PC Serv...

Page 30: ...to 29 rules To setup each schedule please press Schedule Setting then user can get the Schedule List page as following Please click the button to switch between Schedule Setting Schedule list The sch...

Page 31: ...at the desired actions during the time specified 3 Select the Time Period 4 Choose the Action Enable power by clicking in the small square to mark v and select one from the power action of OFF ON RESE...

Page 32: ...efresh and new setting display in Scheduler list Delete Click Delete button to remove a rule from the list 4 2 3 Ping The Ping function allows the device to Ping an IP Address automatically to act as...

Page 33: ...terval The number of seconds Sec between each ping Respond Time Out The number of milliseconds ms of the device will wait for a response from the Pinged device if no ping is detected within this time...

Page 34: ...OR Execute Action by either one IP Host failure as setting 2 pcs IP Host And Execute Action by both IP Host failure as setting 2 pcs IP Host Single 9820 MT will Ping one IP address As the IP fail time...

Page 35: ...Enable Ping function In the selected Rules number please select the outlet number power to activate as ping fails and then press Apply Rule Action button to confirm the setting Ping failure action Whe...

Page 36: ...ows the 9820 MT to obtain an IP Address automatically from user s server connected to Internet Recommended for users who need to control through Internet Please do fill up the correct gateway port for...

Page 37: ...port for login from Internet Please do fill up the correct DNS server for sending receiving email alarm C UPNP With UPNP function user can log in webpage through Internet without setting Port forwardi...

Page 38: ...l Setting User can get e mail advice as one of the following situation happen Receive E mail with IP information MAC Address as 9820 MT device boot up Receive E mail as ON OFF status change in each ou...

Page 39: ...uire As use Gmail account please enable this function User Login for the e mail address Ex 9820 MT gmail com Password Password for the e mail address EX 12345678 From Mail sender address to send the E...

Page 40: ...Turn ON the function Less secure app access Procedure Go to your google account Security Turn ON the function Less Secure appsaccess Please refer the following 3 pictures Go to the management part of...

Page 41: ...f your gmail account turn ON the function 2 Step Verification Please turn it off as following picture or use another gmail account POP3 Control User can control each port turn ON or turn OFF by e mail...

Page 42: ...n the receiver s e mail Ex aviosys1 or aviosys1 gmail com Password Password for the e mail address EX 12345678 Tag User can use any message for 9820 MT to recognize this mail as 9820 MT command mail E...

Page 43: ...name to log in sender s gmail 123 gmail com or abc def com Password to log in sender s gmail 12345678 Command format Example User can get the e mail command contents in the section And execute an e ma...

Page 44: ...xed content 2 POWER1 OFF POWER2 OFF POWER3 OFF POWER4 OFF This is to set the outlet number POWER1 and action ON OFF user can only control 1 4 port ON OFF by e mail Do each outlet command EX Put 14ON i...

Page 45: ...enter the necessary information into the 9820 MT DDNS settings Note The DNS server will have extra change as apply new account Account the Username account name of DDNS account Password the Password o...

Page 46: ...er can select Read only or Read Write In Trap type user can select v1 trap v2c trap or v2c inform In MIB file section user can get MIB information B Telnet In This section is for development of system...

Page 47: ...47 C Modbus TCP A Modbus We supply 3 models of ModBus control C 1 ModBUS TCP Just Enable or disable this function...

Page 48: ...odbus Enable RTU fill Modbus ID C 3 Modbus RTU Need to Enable Modbus Enable RTU fill Modbus ID D BACnet TCP In this section is for development of system integrator who is familiar with Telnet to enabl...

Page 49: ...ith this feature anyone can find its device with no problems IP Service Server Allows user can find user of 9820 MT on the internet without having to remember long IP Addresses Instead user can just r...

Page 50: ...rt Forwarding user device to be able to use it Only some devices are CNT compatible Please refer page 14 for the function of IP Server B CNT MQTT For developing only 9820 MT supports MQTT fucniton Ple...

Page 51: ...ting Langrage Settings NTP settings Import Configuration files and System Reset Administrator setting In this section allows user to change password for 3 different authorization level The account nam...

Page 52: ...e Password Admin Admin 12345678 Operator user user Viewer guest guest Note Please amend the password as number or English character from 1 to 8 characters Do not use special symbol like Please click A...

Page 53: ...k to import please do read following notice Do NOT import DAT file which is not export form 9820 MT The warranty will be invalided if any wrongdoing from Import Please do Import the file in LAN Ethern...

Page 54: ...e power reboot 4 5 2 System Information User can get the system information here 4 5 3 System Log In this section user can get the 9820 MT system operation information and send the information to assi...

Page 55: ...FB QQ AIM Yahoo messenger etc 2 Check to make sure that all devices are turned on safely and powered 3 While updating do not turn off the power 4 Make sure that the cable is connected firmly 5 Do not...

Page 56: ...dress 192 168 1 18 Username admin Password 12345678 1 1 http admin 12345678 192 168 1 18 set cmd cmd getpower 1 2 http 192 168 1 18 set cmd user admin pass 12345678 cmd getpower The above 2 way also f...

Page 57: ...Example Turn on POWER1 and POWER2 and turn off POWER3 http 192 168 1 18 set cmd cmd setpower p61 0 p62 0 p63 0 p64 0 p65 1 p66 1 p67 1 p68 1 System return CGI Command Data follows p61 0 p62 0 p63 0 p6...

Page 58: ...58 5 2 Telnet Control Please enable the telnet function in Application Communication Or Check page 41 to check and enable the function...

Page 59: ...tivirus software firewall temporary Power If there is no power go to 9820 MT please check the fuse part There will be no power for 9258 if the fuse buttons is pup up not easy flexible to press as it w...

Page 60: ...east To reset to original manufacture settings press the reset button with a sharpen pin for 10 seconds then RELEASE There will be 3 beeps sound which means reset start and 9820 MT will be rebooted it...

Reviews: