PERIODIC MAINTENANCE
All Eagle Power machines are engineered and built to require a minimum of maintenance. But like any
machine, it does require some care to keep it in optimum working condition. Careful attention to these
maintenance instructions will give you maximum operating performance and will increase the life expectancy
of your machine.
•
Solution Lines and Fittings. Flush the machine at least once a month with a solution of 1 part water
with 3 parts white vinegar in order to neutralize the alkaline residue left by the cleaning solution.
•
Quick connect coupler. Spray with INOX or lubricant to prevent coupler from sticking.
•
Solution pump. The same above procedure used on solution line and fittings applies to the pump.
TROUBLESHOOTING
ELECTRICAL SYSTEM
Problem
Possible Cause
No electrical power.
1. Defective power cord.
2. House or building circuit breaker tripped.
Switch is turned on.
1. Faulty electrical cable.
Power is intermittent to
2. Defective switches.
all motor(s)
3. Loose terminal or discolored terminal connections.
VACUUM SYSTEM
No Vacuum or Low Vacuum
1. Vacuum filter between tanks is clogged.
2. Vacuum hose is not tight onto recovery tank inlet tube.
3. Recovery tank is not firmly clamped down onto solution tank.
4. Vacum gasket located between the recovery and solution tanks
is worn or damaged.
SOLUTION SYSTEM
Pump motor on, no
1. Clogged spray tips.
spray thru spray tips
2. Clogged solution intake filter screens.
3. Plugged quick disconnect coupler.
Uneven or weak spray
1. Clogged or dirty spray tips.
from tips.
2. Accumulated dirt on solution intake filter screens.
3. Accumulation of debris inside pump and plumbing.
4. Worn nozzles.