HydroCart Compact Operating Instructions
SETUP
1.
The machine may be operated standing upright or lying down.
Choose the position that offers the most stability at the job site.
2.
Cho
o
se a location close to the water supply tap if possible.
Extension
garden hoses may be used but must be 5/8 inch inside
diameter or
larger to minimize line pressure loss. Additional
extension garden
hoses may decrease system volume production
rate.
STARTUP
1.
Connect water supply garden hose to feed water inlet connection.
2.
Connect the yellow
50
ft hose to pure water outlet connection.
3.
Connect wash pole hose to the other end of the
5
0 foot hose.
4.
Connect waste water hose to an area that can accept the water such as
shrubs, trees, grass or drainage that leads to a storm drain. Attach an
extra garden hose if needed to reach the desired area.
Note:
The waste water will not harm any plant life. It is just tap water with a higher
total dissolved solids content.
5.
Turn on water supply.
6.
Test water at the brush using the handheld TDS meter. Water should be less than 10 ppm.
7.
Use the ball valve at the pole to adjust desired amount of pure water supplied to brush.
SHUTDOWN
1.
Turn supply water off.
2.
Let the water drain out of the waste water
hose
.
3.
Connect the end of the waste water hose to the inlet of the Carbon/Sediment
filter for
transport
and to keep the system from drying out.
p. 7
Summary of Contents for Ultra Pure Systems Hydro Cart Compact
Page 16: ...p 16 Notes...