5.9 The machine will not move forwards or backwards.
- The switch in the driver's seat is broken.
- Check the fuses
- Insert the battery plug into the machine socket.
- Turn key switch.
- Lock the plug at the red emergency lever
- Release parking brake.
6. Service and maintenance
6.1
Before any cleaning or servicing work is carried out on the machine and before any parts are replaced, the
following precautions must be taken: the machine plug must be removed from the battery socket, the key must
be removed from the key switch and the parking brake must be applied so the machine cannot move.
When leaving the machine, the operator should apply the parking brake to ensure the machine does not move
unexpectedly.
IMPORTANT:
Before changing the main fuse, it is ESSENTIAL that the battery cabling is disconnected
from the batteries.
6.2
ATTENTION:
Only valid for Titan 351 BF 140
The level of brake fluid in the brake fluid reservoir behind the driver's seat should be checked regularly once a
week and topped up if necessary. The brake fluid should be replaced completely once a year.
IMPORTANT:
Brake fluid is corrosive and toxic. HANDLE WITH CARE, AVOID SPILLS AND DISPOSE OF
APPROPRIATELY.
6.3
The tyres should be examined at regular intervals and any foreign matter such as fragments of metal, splinters
of broken glass etc should be removed.
6.4
Check the state of the squeegee blades regularly and turn or replace if worn. See also 5.4 and 5.5.
6.5
The filters in the clean water tank should be cleaned regularly at least twice a week.
6.6
The vacuum motor, water pump and solenoid valve are below the water tank. The vacuum motor ventilation
slits must be checked regularly for blockages and cleaned if necessary. This is especially important when the
dirt includes large amounts of fluff.
6.7
The dirty water tank should be rinsed out regularly with the drain hose open (to drain the washing water), to
prevent the formation of bacteria. After finishing cleaning, leave the lid open to allow drying.
IMPORTANT:
After each cleaning cycle, the tank should be raised and left open in order to avoid
damage to the lid gasket.
6.8
If not used for long periods, leave the machine with the battery charged and the battery plug unplugged.
6.9
A general control by authorised IPC GANSOW personnel is recommended at least once every six months.
6.10 Faulty or unused batteries should be disposed of correctly.
6.11 For more information on our branches and authorised distributors in Germany and other countries, see the list
of addresses below.
IMPORTANT:
Rooms where batteries are being charged should always be well ventilated.