background image

 

 
 

9. 

Inspection and maintenance list 

 
 
 
 

 

weekly 

monthly 

¼ yearly 

½ yearly  yearly 

1.  General: 

 

 

 

 

 

 

Check brush head 

 

 

 

 

 

Check position and condition of brushes 

 

 

 

 

 

Check the brush head is horizontal and flat when in the 

operating position 

 

 

 

 

 

 

Check clean water tank and dirty water tank for leaks 

 

 

 

 

 

Check that switches are working and lights are not blown. 

 

 

 

 

 

 

Check BEM (hour counter) 

 

 

 

 

 

Dismount and clean the vacuum motor 

 

 

 

 

 

Check the vacuum motor is working properly 

 

 

 

 

 

Check the squeegee blades 

 

 

 

 

 

Check the squeegee is in the correct position on the floor when 
suction is on 

 

 

 

 

 

 

Dismount suction hoses and clean 

 

 

 

 

 

Check the drive motor gearbox for leaks (

if there are leaks      

please call the Gansow Service immediately

 

 

 

 

 

 

Check tyres for the presence of foreign matter or wear 

 

 

 

 

     Clean bayonet and brush connection 

 

 

 

 

2.  Motors 

 

 

 

 

 

 

Check the carbon brushes of the traction motor 

 

 

 

 

 

Check the carbon brushes of the brush motor 

 

 

 

 

3.  Drive system 

 

 

 

 

 

 

Check whether the motor cables are damaged or loose 

 

 

 

 

     Check whether the drive pedal is moving smoothly (without play)   

 

 

 

4.  Dirty water tank 

 

 

 

 

 

 

Clean electrodes 

 

 

 

 

 

Check outlet hose for damage  

 

 

 

 

 

Check suction pipes and hoses for blockages  

 

 

 

 

 

Check cover sealing 

 

 

 

 

5.  Battery 

 

 

 

 

 

 

Check battery cable and connectors 

 

 

 

 

 

If not used for long periods, leave the machine with the battery 

charged and the battery plug unplugged. 

 

 

 

 

 

 

Check that cell caps are safe and not damaged (

does not apply 

to GEL batteries

 

 

 

 

 

 

Check acid level in each cell (

does not apply to GEL batteries

 

 

 

 

 

Grease terminals (

does not apply to GEL batteries

 

 

 

 

6.  Drive control unit

 

 

 

 

 

 

 

Clean control unit (blow out with compressed air) 

 

 

 

 

 

Check that contacts are clean and weld free 

 

 

 

 

 

Check fuses 

 

 

 

 

 

Check that cable connections are firmly secured (false 
connections) 

 

 

 

 

7.  Machine control unit

 

 

 

 

 

 

 

Clean control unit (blow out with compressed air) 

 

 

 

 

 

Check that automatic fuses are firmly in position 

 

 

 

 

 

Check connectors are firmly connected 

 

 

 

 

Summary of Contents for TITAN 151BF 87

Page 1: ...Translation of the original operating instructions Machine models TITAN 151 BF 87 TITAN 351 BF 140 IP Gansow GmbH Dreherstra e 9 D 59425 Unna www gansow de...

Page 2: ...arts are replaced the following precautions must be taken the machine plug must be removed from the battery socket and the key must be removed from the key switch Apply the parking brake whenever work...

Page 3: ...attery is connected the BEM performs a power on self test for approximately 3 seconds Afterwards machine operating hours are shown with a resolution of 0 1h The capacity indicator is activated by turn...

Page 4: ...detergent flow until light pressure is exerted on the forward motion pedal 3 6 The squeegee is lowered by pressing the button with the suction motor icon at the bottom on the right side It is lowered...

Page 5: ...s released the drive motor slows down and stops 4 6 The parking brake should be applied to prevent the machine from moving by accident 4 7 Empty the dirty water tank into a recipient or a drain using...

Page 6: ...g from the squeegee to the dirty water tank and the connectors inside the dirty water tank are not blocked 5 4 The squeegee with suction is leaving smears Clean the rear squeegee blade Check the rear...

Page 7: ...examined at regular intervals and any foreign matter such as fragments of metal splinters of broken glass etc should be removed 6 4 Check the state of the squeegee blades regularly and turn or replac...

Page 8: ...ve motor 36 V 0 600 kW 1 4 kW Vacuum motor 36 V 1 x 0 670 kW 2 x 0 658 kW Brush motor 36 V 2 x 0 650 kW 3 x 0 650 kW Air circulation 2 1 m min 2 4 m min Vacuum max 1800 mm WS 2050 mm WS Sound pressure...

Page 9: ...otor X Check the carbon brushes of the brush motor X 3 Drive system Check whether the motor cables are damaged or loose X Check whether the drive pedal is moving smoothly without play X 4 Dirty water...

Page 10: ...nly for Titan 351 BF 140 X Check rear brake linings X Check position and effect of parking brake X 9 General inspections Have the machine checked by an electrician X Have the machine serviced X IP Gan...