Technisch manual IPC MicroTimer
IPC Systems B.V.
Technisch manual IPC MicroTimer
Pagina 12
Versie 1.3
Ontwikkelingsspecificaties, wijzigingen voorbehouden
Datum 14-03-‘02
Control diagram:
3
Operation in general
The timer starts with the pre-time. During the pre-time, the duration of the main-time will blink in the
display. The duration of the main-time can be limited during the pre-time by activating the Stop timer
button. The pre-time is programmable from 0 up to 255 minutes. The pre-time can be skipped by means
of the quick start function by activating the Start / Pause button. The main-time will follow automatically
after the pre-time. During the main-time the remaining time will appear on the display. The main-time is
programmable from 0 up to 2550 minutes.
The main-time can temporarily be interrupted by activating the Start / Pause button. The post-time will
follow automatically the main-time and is programmable from 0 up to 255 minutes. During the main-time
both relays are active, during the pre-time and the post-time, only relay 2 is active. During the post-time,
the message “CL” (cool) will appear in the display. The timer can be stopped by pushing the Stop
button. If the Stop button is activated during the main-time, the post-time will automatically be initiated.
When the Stop button is activated during the pre-time, the main-time will be shortened with 1 minute.
Relay control diagram:
–S software version,
(signal output)
–P software version
(pulse output)
Standard display
Timer
Relay 1
Relay 2
Relay 1
Relay 2
Stand-by
Off
Off
Off
Off
- (hyphen)
Prior time
Off
On
Pulse
Off
Main time blinking.
Main time
On
On
Off
Off
Remaining main time
Pause
Off
On
Off
Off
Main time blinking.
Post time
Off
On
Off
Pulse
CL
Prior time
Main time
Post time
Pause
- S software version
- During the prior time, contact 2 is closed.
During the prior time, the display blinks with the
value of the main time.
- During the main time, both contacts are closed
(relay 1 & 2). The display shows the remaining
time. The Pause key can be used for temporary
interruption of the main time.
- During the post time, only contact 2 is closed.
During the post time the display shows "CL".
–P software version
- During the prior time, relay signals will not be
confirmed. During the prior time, the set value of
the main time will be displayed blinking.
- When the main time begins, MicroTimer will
send a pulse to relay. The remaining time of the
main time will be shown on the display.
- When the post time begins, MicroTimer will
send a pulse to relay 2. The display will show
“CL”.