3. Plug the Cat5 cable into the A
udio
connector on the Control Mount and the RJ-45 jack
on the wall plate, as shown in Figure 3.
4. Install the wall plate into an electrical box in the room near the audio system.
IMPorTaNT: Do not install the iPort’s wall plate
in the same electrical box as aC house wiring,
a light switch, or any other high-voltage device
or control. The wall plate can share gang boxes
with other iPort Control Mount wall plates or
with controls such as a/B speaker switches,
infrared receivers, and volume controls, if
these other devices are rated as Class 2 devices
according to the National Electrical Code.
5. Use a stereo RCA audio cable to connect
the wall plate’s A
udio
connectors to a
source input on the local-zone audio
system, as shown in Figure 3.
6.
Prior to placing the mounting cradle into
the wall, pull a sufficient length of the Cat5
cable and its attached RJ-45 connector
through the opening in the lower corner of
the mounting cradle, as shown in figure 4.
7.
The retainer and cradle are pre-assembled
with
internal
packaging
materials.
Disassemble by removing the four screws.