In this welding process, a filled wire is used for welding, which already contains particles that form a
protective atmosphere during welding and thus prevent air from entering. You do not need shielding
gas for this welding process.
When you select FLUX, the welding machine automatically adjusts some parameters to help you
achieve the best results during welding.
Use the control knob (4) to set the appropriate welding current, which is usually set in the range of
approx. 80A when filling with charged wire. Then place the control knob (5) in the middle. During
welding, both control buttons must be adjusted until you get a satisfactory or a desired weld.
Shielding gas welding
Depending on which shielding gas you want to work with, press the button (3) to set the "Co2" or
"MIX" selection:
If you use CO2 as the shielding gas, set the "Co2" setting with the button, or if you use the argon /
CO2 mixture as the shielding gas, you must select the "MIX" setting with the key.
Use the control knob (4) to set the appropriate welding current depending on the diameter of the
welding wire. Then place the control knob (5) in the middle. During welding, both control buttons must
be adjusted until you get a satisfactory or. of the desired weld.
MMA Welding
Connect the welding cable and the earthing cable to the socket (7, 8) with the appropriate polarity
according to the electrode manufacturer's recommendation.
Pay attention to positive and negative attachment. Different types of electrodes require
different polarities, see electrode manufacturer's instructions.
* In TIG mode (LIFT TIG), connect the cables in the same way as in the case of "A rutile
electrode ".
Polarity:
The polarity depends on the information provided by the electrode manufacturer on the electrode