Better Packages
Section 4
Maintenance
28
• If the fuse is blown, replace it with one rated at AL T2 250V.
• If the fuse is OK and the system is still not working, contact your dealer for
service or call Better Packages for assistance at:
1-800-237-9151
(in the US only) or
1-203-926-3700
(outside of the US)
LUBRICATION
The blade oiler is a felt pad that presses lightly on the back of the shear blade.
1. Turn the dispenser off and unplug it.
2. Pull back gently on the blade oiler to move it away from the shear blade.
3. Keep the felt pad slightly moist by adding several drops of light machine oil at regular weekly or
monthly intervals depending on use. Do not over-oil. The oil will keep your shear blade lubricated for
clean, fast cutting.
4. Gently push the oiler back into position next to the shear blade.
5. Plug the dispenser back in.
FUSE (A break in the
filament indicates the
fuse is blown.)
FIGURE 22 - Fuse Holder Location
FIGURE 23 - Blade Oiler Location
Blade Oiler
(Pushed away from shear blade)