background image

MANUFACTURER'S EXTENDED WARRANTY

In addition to your statutory rights relating to this product it is also guaranteed by IQ (Europe)
Limited ("IQ") for 12 months from the date of purchase against faulty materials or workmanship
which affect its designed ability to detect or switch.  During this period if the product has a defect
of this nature it will be repaired or replaced free of charge by IQ with the same item, or a similar
one of higher specification, ON CONDITION THAT:-

The buyer takes advantage of any 'return to store' scheme operated by the seller from whom it is
bought.

If the product has a defect outside the period of any seller's 'return to store' scheme it should be
returned to IQ (Europe) Limited at Sandbeck Lane, Wetherby, W. Yorks LS22 7TW, England at
the expense of the buyer together with evidence of the date of purchase (it is the responsibility of
the buyer to prove delivery to IQ).

The product has been bought by the user.

The product has not been misused or handled carelessly, installed incorrectly, or used on a 
voltage supply other than that shown on it.

Repairs have not been attempted by anyone other than IQ's staff.

The product has been used for domestic purposes only.

The product has not been installed in any unusually exposed or harsh environmental conditions.

If the buyer is resident in the EU the product or its replacement will be returned to the buyer at
the expense of IQ. 

This guarantee excludes liability for discolouration of paint or plastic, or any user replaceable
parts and in particular lamps, glass panels, or globes/lanterns. It does not confer any rights other
than those expressly set out above and does not cover any claims for consequential loss or 
damage. 
This guarantee is offered as an additional benefit and does not affect your statutory rights as a 
consumer.

This contract is subject to the laws of England and Wales.

*** IMPORTANT ***

As of 1 January 2005, changes to the Building Regulations affect domestic electrical installations in

England and Wales. You don't need to be a qualified electrician to make changes to your home's electrical

system, but the work must be done in accordance with the Regulations. 

Where you employ an electrician who is a member of a competent person self-certification scheme, they

will be able to certify the work complies with the Regulations.

If you decide to carry out the work yourself we recommend that you make yourself aware of the

Regulations before you begin and if you require any clarification you should contact your Local Authority

Building Control Department.

Details of the Building Regulations can be obtained on the internet via the government website

www.odpm.gov.uk/explanatory-booklet 

SF-LA-BC-RX-W.qxd  13/04/2005  13:36  Page 2

Summary of Contents for E-997

Page 1: ...R G U I D E Lantern Receiver E 997 IQ Europe Limited Sandbeck Lane Wetherby LS22 7TW Visit us at www iq europe co uk Installation helpline 0871 717 1100 V1 0 04 05 IQLA BC RX W SF LA BC RX W qxd 13 04 2005 13 36 Page 1 ...

Page 2: ...environmental conditions If the buyer is resident in the EU the product or its replacement will be returned to the buyer at the expense of IQ This guarantee excludes liability for discolouration of paint or plastic or any user replaceable parts and in particular lamps glass panels or globes lanterns It does not confer any rights other than those expressly set out above and does not cover any claim...

Page 3: ...be within transmission range of your PIR transmitter Tx We suggest that firstly that the Tx is placed in its optimum position to give the coverage and detection required then the Receiver is located indoors at a point where it can receive the Tx s signal 1 Position your PIR Tx in desired area perform walk tests to confirm detection zones 2 Chose your preferred location for the Lantern Rx up to 60m...

Page 4: ...main off for a short period After this short period the light comes ON to indicate the programming period has begun the Lantern RX LED will flash slowly See diagram I 5 To activate the Sensor s signal to the Receiver walk in front of the Sensor the Sensor s LED flashes red indicating motion has been sensed and a signal has been transmitted The lamp will now illuminate for 5 seconds after each dete...

Page 5: ...TIME SET BY THE USER AND THE LED WILL FLASH ON OFF FOR APPROX 5 SECONDS 2 DUSK TIMER To set how long the light remains ON after dusk set the DUSK TIMER dial to 2 4 8 hours or DUSK DAWN After dusk the light will turn on in DIMMED MODE for the time you set If motion is detected by the DC PIR TX the light turns ON for the length of time you have set using the ON TIME dial then will return to DIMMED M...

Page 6: ...o prevent inadvertent programming by other transmitters remove then gradually add batteries or turn on power to the Tx you want coded to the Chime Rx during the AUTO PROGRAMMING Mode SECTION FOUR TECHNICAL SPECIFICATION LANTERN RECEIVER Power Supply Maximum Switchable Load Time On Adjustment Dusk Timer Adjustment Dimmer Transmission Range 230 240 V AC 50Hz 75W Max BC GLS or 23W Compact Fluorescent...

Page 7: ...see previous section You may not be allowing the unit time to complete it s warm up period Stand well out of the detection range and wait the warm up period should never exceed 1 minutes Occasionally winds may activate the sensor Sometimes passages between buildings etc can cause a wind tunnel effect Ensure the unit is not positioned so as to allow detection of cars people using public thoroughfar...

Page 8: ...ng path of Sensor s signal transmission To check signal path set Receiver s on time dial to Test Remove Sensor from bracket recover photocell if daylight As you walk the Sensor around the Receiver wave your hand in front of Sensor Note when it turns the Receiver ON Remount Sensor in that area 7 Check the lamp If the lamp has failed replace The level of ambient light in the area may be too bright t...

Page 9: ...annoyance over lighting an area can cause to your immediate neighbours Light pollution caused by incorrectly installing a unit or over lighting an area can be limited by carefully considering the location and position of your unit before installation The light spread on all halogen floodlights can be reduced by angling the floodlight downwards on the mounting bracket This will also concentrate the...

Reviews: